EDR-240-24 240W 24VDC 10A DIN Rail Switched Mode Power Supply

Min.Order: 10
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 33.82 ~ 39.08

Description
240W Single Output Industrial DIN Rail Power Supply       EDR-240 series
Features:
Universal AC input/ full range
Built-in active PFC function
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
1 year warranty
SPECIFICATIONS
OUTPUT 
ModelEDR-240-24EDR-240-48
DC Voltage 24V48V
Rated Current 10A5A
Current Range 0-10A0-5A
Rated Power 240W240W
Ripple & Noise 150mVp-p360mVp-p
Voltage Adj. Range 21-28V43-53V
Voltage Tolerance ±1%±1%
Setup, Rise Time 800ms,40ms/230VAC   800ms,40ms/115VAC at full load
Hold Up Time 24ms/230VAC   24ms/115VAC at full load
Voltage Range 176~264VAC   47~63Hz; 240~370VDC
AC Current2.8A/115V   1.4A/230V
Efficiency84%85%
Inrush Current Cold start 27A/115V   45A/230V
Leakage Current<3.5mA/240VAC
Over Load 105%~150%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 30-36V54-60V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp.100ºC±5ºC(TSW1)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
Working Temp., Humidity-10ºC~+70ºC; 20%~90%RH
Storage Temp., Humidity-20ºC~+85ºC; 10%~95%RH
Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
Withstand VoltageI/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
Safety StandardDesign refer to UL508,UL60950-1, TUV EN60950-1
EMC StandardEN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)
Dimension63*125.2*115mm(L*W*H)
Weight0.85Kg
Packing20pcs/17.5Kg/1.2CUFT
NOTE 
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3 .Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5 . Derating may be needed under low input voltages. Please check the derating curve for more details.

 

Product Description


 