Medical Equipment HEA313 Enteral Feeding Pump
Technical specification
Infusion rate (ml/h) | 1~400 ml/hr in 1 ml increments |
Mean flow velocity accuracy | ±10% of selected flow rate |
Dosage limit(ml) | 0-9999 in 1 ml increment |
Meanvolume accuracy | ±10% |
Loading speed andmeanaccuracy (ml/h) | 1000±10% |
Cleaning speed andmeanspeedaccuracy(ml/h) | 1000±10% |
Max volume flushandmeanspeed accuracy(ml) | 40±10% |
Mx feeding pump pressure | ≥0.1 MPa |
Occlusion alarm level (pressure) | 50KPa±10KPa |
The longest occlusion triggering time of this device at minimum flow rate | 43min |
The shortest occlusion triggering time of this device at intermediate flow rate | 85s |
Medium speed running the pills from blocking the alarm threshold | 0.79ml |
Recoverable Alarm | 1min50s-2min |
Pause overtime alarm time | 1min50s-2min |
Heating temperature | Infusion flow rate ≥20ml / h, 375px distance away from the heater outlet at 25-38 ºC |
Use ofinfusionset | See recommended infusion sets list |
Air-in-line sensitivity | Detestability of single size of air bubble ≥50uL |
Alarm | Occlusion alarm, Over heatedalarm, battery depleted alarm |
Alarms | Air in line,Prime, Flush, low power, failurecodes (ERxx), pause overtime, powerstate, infusion mode, work state, heaterstate. |
Noise | Measured at the highest flow rate on wooden table, the volume is lower than 50 dB at a distance of 1 meter |
Power | Ac: 100V-240V 50 Hz /60Hz |
Built inbattery | A fully charged internal DC11.1V battery can continuously run the pump for approximately 5 hours on intermediate rate |
Power consumption | ≤40VA |
Power output | ≤20VA |
The rated output voltage | 15V |
Weight | 2.0kg |
Heater | W-E01 ,cable length is 1.5m,Shield |
Essential performance | This product is suitable for patients with enteral nutrition infusion, the host cancontrol the infusion rate. With alarmfunction, with bubble detection piping and piping blockage detection. |
Classification | type BF,class ΙΙ continuous volumetric feeding pump with internal battery; IPX1 (sealed drip-proof device) |
Dimensions | 155mm(L)×170mm(W)×180mm(H) |
Accessories | 1 user manual, 1 power cable, 1 heater (EA312/313 models only) |
1. What about the price level?
We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts.
2. Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same?
As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper.
3. What is time of delivery?
Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible.
4. What about quality assurance?
We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge.
5. What is payment terms?
T/T, Credit Card, L/C, Western Union, PayPal, MoneyGram.