1 | Product gas: | Oxygen (O2) |
2 | Gas production capacity: | 50Nm3/h |
3 | Oxygen purity: | 93% |
4 | Oxygen recovery rate: | ≥40% |
5 | Oxygen dew point: | ≤-45ºC |
6 | Operation mode: | Automatic unattended control |
7 | Detection method of oxygen content: | On line detection |
8 | The device has capacity expansion capacity: | 10% design margin |
9 | Flexibility of system operation: | Adjustable within the rated range |
10 | Valves: | Screw type |
12 | Design pressure: | 0.8MPa |
13 | System operating pressure: | ≤ 5bar (adjustable according to customer's site requirements) |
14 | Filling pressure: | 200bar |
15 | System pressure loss: | ≤ 5% (pressure loss at inlet and outlet) |
16 | System design service life: | 10-15 years |
19 | Explosion proof requirements for system design: | Non explosion proof design |
20 | The degree of automation of system design is as follows | Automatic unattended |
name | Voltage | power |
screw compressor | 3Ph,220V,60HZ | 90KW |
Freeze dryer | 3Ph,220V,60HZ | 3.5KW |
oxygenerator | 1Ph,220V,60HZ | 0.2KW |
Oxygen booster | 3Ph,220V,60HZ | 18.5KW |
total | 113.2KW | |
It takes two tons of water to circulate |
production | Oxygen generator: according to jb6427 / 92 standard Pressure vessel: according to GB 150-1998 standard Welding: according to JB / t4709-92 standard Wire arrangement and installation: Standard gb5226-96 Iso9001:2016 certification Iso13485:2016 certification CE EU certification |
inspect | Oxygen content detection: range: 21% ~ 98% Flow test: flowmeter Acceptance standard: according to the contract and the buyer's requirements Before acceptance, it can be installed and debugged on site. |