Kvtester 10kv Insulation Tester High Voltage Insulation Resistance Tester

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 999 ~ 1299

Description

Features




It features of microcomputer control, menu operation, large-screen LCD dot matrix display, and stable performance, and it is the intelligent instrument. 

With a strong ability to resist the interference, it is applicable to the measurement in an environment with severe electromagnetic interference. 

It is equipped with 8 voltage output gears, namely 50V, 100V, 250 V, 500V, 1.0kV, 2.5kV, 5.0kV,10.0kV. 

When the high voltage is output, it can be regulated continuously as well. 

It has strong load capacity, and the short-circuit current is about 5mA. 

Measuring range: 0 to 10GΩ, and it can switch the range automatically. 

The combination of simulation bar pointer and digital display can show the change trend of data and accurate measuring results. 

The testing time can be displayed at any time, 

After the completion of measuring, it will discharge the high voltage automatically, and the discharging time of high voltage is no more than 30 seconds. 

It can measure the ambient temperature, air humidity and the date and time of each testing automatically. 

The test condition, 5 minutes without any operation, instrument tips to turn it off.

It has the comprehensive perfect protection function, therefore the operational reliability is high.


Product Parameters
 
Rated testing voltage50V, 100V, 250 V, 500V, 1.0kV, 2.5kV, 5.0kV,10.0kV, 8 voltage output gear in total
Upper limit of measuring range0 ~ 10TΩ
Lower limit of measuring range0.1MΩ
Output voltage error±5%
Short-circuit currentApprox. 5mA
Grade of accuracyGrade 5.0
Basic error of second half measuring range±( 5%·Rx + 1d )
Basic error of first half measuring range±( 10%·Rx + 2d )
High voltage display error±( 5%·Ux + 1d )
Temperature measuring error±0.5ºC
Air humidity measuring error±2%RH
Power supply14.8V lithium battery
Service life of battery after one-time charging30 days, 10 times of DAR and 5 times of PI test for each day
Insulation resistance> 500 MΩ (between the test line and machine case)
Voltage resistanceAC10.0kV 50Hz 1min(between the test line and machine case)
Working temperature and humidity0ºC ~ + 40ºC < 85%RH
Storage temperature and humidity- 20ºC ~ + 50ºC < 90%RH
Boundary dimension270 (L) X 240(W) X 165(H) (mm)
Weight≈ 4.5kg

 








 