Infrared Sensor Carbon Steel UV Lamp Trolley 4-Tube

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 285 ~ 398

Description
Infrared Sensor  Carbon Steel UV Light Car/ trolley
 
Details discription
This product is made of carton steel,with its four-tube structures, but also can be used independently .
Ultraviolet sterilizing trolley is mainly used in the medical and hygienic units as well as the industrial section of food and medicines for the air sterilization.
 
Technical Parameters:
Item:
UV Lamp Trolley
Size:
119*42*38cm
Model:
FY-30FCI
weight:
24kg
UV lamp&Power:
4*30W
Irradiance:
≥ 428uw/cm2
Voltage:
220V/110V
Application:
Air sterilization
Timer:
0-1440minutes
Disinfection CBM:
≥60m2
Matched Ballast::
Lowering Energy Consumption
Wavelength:
253.7nm
Material:

carbon steel
lamp arm adjustable angle:
0~180 degree
Method of usage
This product can be used alone with double light tubes, and the angle of the lamp arm can also be adjusted.
Please close the safety door when it is not in use in order to avoid the damage of the light tube and also maintenance of the cleaning of the tubes. The timer can control the sterilizing time within 1440 minutes.
And the circuit will be automatically closed when time is up. Every part of the truck should be tested beforehand in order to check whether it has the problem of leakage of electricity. And three-pins plug must have a land wire in order to avoid the electric shock. Please cut the electric circuit after the truck is used and then withdraw the plug from the socket.

Application place

The High Intensity UVC Lamp trolley is mainly applied in sterilization and disinfection of the air in operating room, ICU, treatment room and ward, it could be also be applied in sterilization and disinfection of other rooms of which the air is required being sterilized. Hospital: operating room, manufacturing laboratory, ward, treatment room, toilet Blood station: blood sampling room, bioclean room, blood bank Food and beverage: manufacturing shop, changing room, laboratory.


Warning

1.The voltage range should be less than 10%,or will affect the rated life.
2.double tube structures,the arm of lamp can be adjustable according to the angle.
3.The timer can set the sterilization time,the power will be cut off automatically.Follow the direction instruction.
4.Ensure the surface clean of UV lamp,or will affect the performance.
5.In case of any electricity risk.
6.After using turn off the plug of power.
7.Keep in the dry and clean room.
8.UV illumination less than 70% or more than 2000 hours working should change the lamp