High quality/High cost performance Dr-30-5 30W 5V AC to DC Easy to Install DIN Rail Power Supply

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 6.8 ~ 8.8

Description
SPECIFICATIONS
OUTPUT 
ModelDR-30-5DR-30-12DR-30-15DR-30-24
DC Voltage 5V12V15V24V
Rated Current 3A2A2A1.5A
Current Range 0-3A0-2.5A0-2A0-1.5A
Rated Power 15W24W30W36W
Ripple & Noise 80mVp-p120mVp-p120mVp-p150mVp-p
Voltage Adj. Range4.75-5.5V10.8-13.2V13.5-16.5V21.6-26.4V
Voltage Tolerance ±2%±1%±1%±1%
Line regulation±1%±1%±1%±1%
Load regulation±1%±1%±1%±1%
Setup, Rise, Hold Up Time 100ms,30ms/230VAC   100ms,30ms/115VAC at full load
100ms/230VAC        21ms/115VAC at full load
Voltage Range 85~264VAC   47~63Hz; 120~370VDC
AC Current0.88A/115V   0.48A/230V
Efficiency74%81%82%83%
Inrush Current Cold start 15A/115V   30A/230V
Over Load 105%~160% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 5.75-6.75V13.8-16.2V17.25-20.25V27.6-32.4V
Protection type: Shut down o/p voltage, re-power on to recover
Working Temp., Humidity-20ºC~+60ºC; 20%~90% RH non-condensing
Storage Temp., Humidity-40ºC~+85ºC; 10%~95%RH
Temp. Coefficient±0.03%/ºC(0~50ºC)
Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
Withstand VoltageI/P-O/P: 3KVAC
Isolation ResistanceI/P-O/P: 100M Ohms / 500VDC/25ºC/70% RH
Safety StandardDesign refer to UL60950-1,TUV EN60950-1,EN50178
EMC StandardDesign refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2,EN61204-3, heavy industry level, criteria A
Dimension78*93*56mm(W*H*D)
Weight0.27Kg
Packing48pcs/14Kg/1.02CUFT
NOTE 
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.