Medical Equipment HEA323 Double Enteral Feeding Pump
Technical specification
Infusion preset range (ml) | Feeding volume: 0-9999, adjusted by 1 Water feeding volume: 0-999, adjusted by 1 |
Infusion(feeding or watering) accuracy | ±10% or±0.2ml/h(choose the larger value) |
Feeding speed setting range (ml/h) | 1~800, adjusted by 1 |
Feeding speed accuracy | ±10% or±0.2ml/h(choose the larger value) |
Water feeding speed and accuracy (ml/h) | 1000±10% |
Flushing speed and accuracy (ml/h) | 1000±10% |
Single Flushing dose (ml) | 25±10% |
Perfusion speed and precision (ml/h) | 1000±10% |
Perfusion dose (ml) | 10ml±10% nutrition and 25ml±10% water |
The Maximum infusion pressure | ≤0.1 MPa |
The trigger alarm time at minimum flow rate | 42min18s |
The trigger alarm time at medium flow rate | 1min30s |
The amount of bolus produced by Medium speed up to the blocking alarm threshold | 0.49ml |
Blocking alarm threshold (pressure) | 50KPa±10KPa |
The recoverable time when alarm is automatically restored after the time is out | 1min50s - 2min |
Pause time when alarm timeout | 1min50s - 2min |
The heating temperature | When the feeding speed is greater than 20ml/h,15cm distance heater outlet is 25-38ºC |
Bubble sensitivity | A bubble that can detect a single volume greater than 50uL |
Intestinal feeder | Special intestinal feeding device |
Alarm function | Tube occlusion, battery exhaustion, overtemperature |
Prompt function | Tubing Bubble, Infusion Completion, Flush Completed, Battery Under voltage, Equipment Failure (ER Series), Pause Timeout, Network Power On / Off, Feeding /watering Switching |
Noise | When operating at the maximum flow rate on the wooden desktop, noise level are below 50dB in the distance of 1 meter at the front, after and above. |
Power supply and input | 100-240V ~ 50 /60Hz ≤40VA |
Internal battery | Internal rechargeable lithium battery 11.1V; battery life > 8 hours |
Output | ≤20VA |
Rated output voltage | DC15V |
Total Weight | About 1.5kg |
Rate | Class II BF type continuous operation capacity type nutrition pump with internal power supply; Class IPX1 (anti-dripping device) |
Dimensions | 135mm (L) ×105mm (W) ×160m (mH) |
Accessory | 1 User's Manual and other document, 1 adapter, 1 set of intestinal feeding device and heater |
1. What about the price level?