High Performance Liquid Chromatography-BK1100
Features:
*LCD display
*Front-mounted self-locking switch
*Small size, easy to place, save space
*Standard configuration USB portspace
Model | BK-LCI1100 | BK-LCG1100 | |
High Pressure Constant Flow Pump | Double plunger reciprocating pump | 1 set | 2 sets |
Flow Range | 0.001mL/min-10.000mL/min | ||
Setting Step Size | 0.001mL/min | ||
Flow Accuracy | ≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | ||
Flow stability | RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) | ||
Maximum Pressure | 42MPa | ||
Display Pressure Error | ≤±3.0% | ||
Pressure Fluctuation | ≤1.0% | ||
Power Dissipation | 80W | ||
UV/VIS Detector | Wavelength Range | 190-700nm | |
Wavelength Repeatability | ±0.1nm | ||
Wavelength Accuracy | ≤±1.0nm | ||
Spectrum Band Width | 8nm | ||
Response Time | 0.0s-4.9s | ||
Linearity Range | 1.8AU (5%) | ||
Baseline Noise | ≤±1×10-5AU | ||
Baseline Drife | ≤2.0×10-4AU/h | ||
minimum Detectable Concentration | 4.0×10-9g/mL(Naphthalene in Methanol Solution) | ||
Detector Cell | Optical Path--10mm, Volume--10μL | ||
Light Source | Deuterium Lamp | ||
Power Dissipation | 100W | ||
Gradient Mixer | / | GM1100 | |
Sampler Injector | 1 | ||
Supersil ODS2 5μm ID4.6×200mm | 1 | ||
Workstation (Without Computer & Printer) | 1 | ||
Valve Mounting Frame | 1 | ||
Kits | Isocratic System Kits | Gradient System Kits | |
Power Supply | AC110/220V±10%, 50/60Hz | ||
Optional Accessory | Column Oven |
Features:
* Adopting mature and reliable mechanical structure, optical structure and circuit structure of core technology
* Stepper motor 64 subdivision control technology to improve accuracy at low flow rates
* Straight-through pressure transmitter
* Scientific air duct design to effectively reduce baseline drift
Technical Parameters:
Model | BK-LCI3100 | BK-LCGH3100 | BK-LCQL3100 | |||
High Pressure Constant Flow Pump | Quantity | 1 Set | 2 Set | 1 Set | ||
Flow Rate Range | 0.001mL/min-10.000mL/min | |||||
Flow Accuracy | ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) | |||||
Flow Precision | RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa) | |||||
Maximum Pressure | 45MPa | |||||
Pressure accuracy | ≤±3.0% | |||||
Pressure pulsation | ≤0.1MPa | |||||
UV/VIS Detector | Wavelength Range | 190-700nm | ||||
Wavelength Repeatability | ≤0.1nm | |||||
Wavelength Accuracy | ≤±1.0nm | |||||
Band Width | 8nm | |||||
Response Time | 0.0s-5s | |||||
Baseline Noise | ≤±0.5×10-5AU | |||||
Drift | ≤1.0×10-4AU/h | |||||
Path length | 10 mm(analytical cell) | |||||
Light Source | Deuterium Lamp | |||||
Low-Pressure Gradient Unit | Integrated vacuum degasser | / | / | 4 channel | ||
Composition Rang | 0-100% | |||||
Composition Precision | ≤0.2% RSD | |||||
Composition Accuracy | ≤±2.0% | |||||
Data-processing Workstation | Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. | |||||
3100 System Kits | 1 Set | |||||
Power Supply | AC110/220V±10%, 50/60Hz | |||||
Optional Accessory | Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector | |||||
Package Size(W*D*H) | 600*440*380mm*4 | |||||
Gross Weight | 68kg |
High Performance Liquid Chromatography- BK5100
Features:
*Highly integrated ARM microcontroller SPI, I2C technology
* Accurate automatic wavelength positioning and excellent wavelength accuracy
* Plunger floating design, more stable output
* Intelligent sequence analysis and batch processing
* Chromatography workstation software meets 21 CFR Part 11
Technical Parameters:
Model | BK-LCI5100 | BK-LCG5100 | BK-LCQL5100 | |
Pump | Type | Isocratic Pump | Gradient Pump | Quarternary Low Pressure Pump |
Flow Rate Range | 0.001-10.000mL/min, in 0.001mL increments | |||
Flow Accuracy | ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) | |||
Flow Precision | RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa) | |||
Maximum Pressure | 63MPa | |||
Pressure accuracy | ≤±3.0% | |||
Pressure pulsation | ≤0.1MPa | |||
Composition rang | / | 0-100% | 0-100% | |
Composition precision | / | ≤0.2%RSD | ≤0.3%RSD | |
UV/VIS Detector | Wavelength Range | 190-800nm | ||
Wavelength Repeatability | ≤0.1nm | |||
Wavelength Accuracy | ≤±1.0nm | |||
Band Width | 6nm | |||
Response Time | 0.0s-5s | |||
Baseline Noise | ≤±0.25×10-5AU(empty cell, 254nm, 1.0s) | |||
Drift | ≤0.5×10-4AU/h(empty cell, 254nm, 60min) | |||
Path length | 10 mm(analytical cell) | |||
Light Source | Deuterium Lamp and Tungsten Lamp | |||
Data-processing Workstation | Sequence tables for any set of samples Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. | |||
5100 System Kits | 1 Set | |||
5100 System Manager | Integrated A/D converters | Integrated A/D converters Integrated vacuum degasser, 4 channel | ||
Power Supply | AC110/220V±10%, 50/60Hz | |||
Optional Accessory | Solvent bottle,Column Oven, Auto-sampler,DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC | |||
Package Size(W*D*H) | 700*570*310mm; 700*570*350mm; 710*583*500mm; 730*450*440mm; 600*440*380mm; 770*450*700mm; | |||
Gross Weight | 156kg |