Model | JCD1200SL/FL | JCD2400FL | JCD4800FL | JCD7200FL | JCD9600FL | JCD10800SL | JCD16200SL | JCD21600SL | JCD27000SL | JCD32400SL | JCD37800SL | JCD43150SL | JCD48600SL | JCD54000SL |
Standard water removal / 24h | 1200kg | 2400 kg | 4800 kg | 7200 kg | 9600 kg | 10800kg | 16200 kg | 21600 kg | 27000 kg | 32400 kg | 37800 kg | 43200 kg | 48600 kg | 54000 kg |
Water removal / h | 50 kg | 100 kg | 200 kg | 300 kg | 400 kg | 450kg | 675kg | 900kg | 1125kg | 1350kg | 1575kg | 1800kg | 2025kg | 2250kg |
Operating power | 15kw | 27 kw | 51 kw | 75 kw | 106 kw | 105kw | 155kw | 205kw | 255kw | 305kw | 355kw | 405kw | 455kw | 505kw |
Heat pump host Number of modules
| 1 set | 1 set | 2 set | 3 set | 2 set | 2 set | 3 set | 4 set | 5 set | 6 set | 7 set | 8 set | 9 set | 10 set |
Cooling method | Water-cooled / air-cooled | Air-cooled | Air-cooled | Air-cooled | Air-cooled | Water-cooled SL | ||||||||
Cooling water flow Δt = 15 ºC
| 0.5m3/h See note 1 | / | / | / | / | 8.5m3/h | 12.8m3/h | 17m3/h | 21m3/h | 25.5m3/h | 30m3/h | 34m3/h | 38m3/h | 42.5m3/h |
The refrigerant | R134a | |||||||||||||
Power supply | (220V\380V\440V)/3H/50Hz(60Hz) | |||||||||||||
Drying temperature | 50 ~ 60 ºC (return air) / 65 ~ 80 ºC (supply air) | |||||||||||||
Control System | Touch screen + PLC programmable controller | |||||||||||||
Application scope of wet sludge | Moisture content (75% -81%) (other water content is customized) | |||||||||||||
Dry water | Frequency conversion adjustment, moisture content (10% -50%, adjustable) | |||||||||||||
Forming method | Cut into strips | |||||||||||||
Dimensions (L * W * H) mm | 3400 *1510 *2180 | 3910 *2350 *2480 | 6610 *2350 *2480 | 9310 *2350 *2480 | 8020 *3150 *3250 | 8020 *3150 *3250 | 11270 *3150 *3250 | 14520 *3150 *3250 | 17770 *3110 *3200 | 20920 *3150 *3250 | 24570 *3150 *3250 | 27520 *3150 *3250 | 30770 *3150 *3250 | 34020 *3150 *3250 |
Structure type | Outfit | Outfit | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly | Assembly |
Weight | 2Ton | 3.2Ton | 5.7Ton | 7.8Ton | 9Ton | 9Ton | 12.3Ton | 15.5Ton | 17.7Ton | 21.9Ton | 25.1Ton | 28.3Ton | 31.5Ton | 34.7Ton |
Note 1: JCD1200FL (air-cooled) model does not require cooling water. 2: Product updates will cause changes in parameters, please contact technology for details. 3: For details of customized models, please communicate with technology.
Features:
Heat pump heat recovery system, 100% total heat utilization.
Moisture content below 10%, reduction over 80%.
Ultra-low operating cost per ton of 180-degree electricity.
50 degrees low temperature operation, safer.
0 emissions, no odorous emissions, condensate can be discharged straight, more hygienic without dust.
Applicapable Industries:
Adopting heat pump and full heat recovery technology for belt drying, the equipment has stable working conditions and high energy efficiency.
Fully-isolated closed drying mode without any waste heat emission, 100% heat utilization.
Dry 80% ton of wet sludge to 10%, comprehensive power consumption 180kwh.
Dry 80% ton wet sludge to 40%, comprehensive power consumption 160kwh.
Dry 80% of wet sludge to 60%, and the comprehensive power consumption is 120kwh.
Each kilowatt-hour can evaporate more than 4.0 kg of water (dehumidifying performance ratio 1: 4.0 kg.H2O / kwh).
The residual heat is small, and the cooling circulating water can be air-cooled and closed water-cooled to save water.