DC motor is a rotating motor that can convert DC electric energy into mechanical energy (DC motor) or mechanical energy into DC electric energy (DC generator). It is a motor that can convert DC and mechanical energy into one another. When it runs as a motor, it is a direct current motor, which converts electrical energy into mechanical energy; when it runs as a generator, it is a direct current generator, which converts mechanical energy into electrical energy.

 
     Induction furnace is used for smelting or insulating ferrous metals, non-ferrous metals, sponge iron, such as scrap iron, scrap steel, copper, aluminum and so on. Complete working equipment such as continuous casting machine, rolling mill, mainly used for the production of billet, steel bar, angle steel, H-beam, I-beam, etc. Using KGPS, IGBT, single or double power supply technology, PLC (Siemens) can be realized throughout the monitoring.
 
       Main supply list: 2 sets of electric furnace body, 2 sets of hydraulic or mechanical tilting electric furnace mechanism, 1 set of control platform, 1 set of intermediate frequency control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), low voltage control cabinet (6 pulse 1, 12 pulse 2, 24 pulse 4), 1 set of capacitor cabinet, 4 or 8 water-cooled cables; 1 water temperature alarm, 1 leakage alarm; 1 crucible mold, 1 liquid One batch of pressure steel pipe, one set of copper row, three water tanks. Transformer, cooling tower, furnace builder, furnace lining ejector, furnace cover.

KGSP Induction Electric Furnace


GW-8-4000-0.5J KGSP Induction Electric Furnace



GW-1-750-1JJ Medium frequency coreless electric furnace


GW-50-22000-0.2J No induction melting furnace


GW-0.25-160-1JJ melting electric furnace

GW-1.5-1000-1J Medium frequency induction furnace






 
NO.Electric 
Furnace 
Type
Input 
power
(KW)
input 
voltage
(V)
Input 
current
(A)
Rated 
power
(KW)
DC 
current
(A)
DC 
voltage
(V)
Melting 
rate
(T/H)
working 
frequency
(HZ)
working 
voltage
(V)
cooling water
 pressure(MPA)
Rated 
capacity
(T)
Power 
consumption
(KWH/T)
Power 
Supply
Furnace 
body
1GW-0.25-160/1JJ180380
(6 Pulse)
2561603205000.2410007500.1~0.150.25~0.30.25790
2GW-0.5-250/1JJ280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
3GW-0.5-250/1J280380
(6 Pulse)
4002505005000.4100015000.1~0.150.25~0.30.5770
4GW-0.75-400/1JJ400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
5GW-0.75-400/1J400380
(6 Pulse)
6504008005000.6100015000.1~0.150.25~0.30.75770
6GW-1-500/1JJ550380
(6 Pulse)
80050010005000.8100015000.1~0.150.25~0.31750
7GW-1-750/1JJ800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
8GW-1-750/1J800380/690
(6 Pulse)
1200/
700
7501500/
850
500/
880
0.91000/
500
1500/
2600
0.1~0.150.25~0.31720/660
9GW-1.5-1000/0.5JJ1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
10GW-1.5-1000/0.5J1100690
(6 Pulse)
912100011408801.250026000.1~0.150.25~0.31.5700
11GW-2-1500/0.5JJ1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
12GW-2-1500/0.5J1650690
(6 Pulse)
1360150017008801.750026000.1~0.150.25~0.32675
13GW-2-2000/0.5JJ2200690
(6 Pulse)
1400200022758801.950026000.1~0.150.25~0.32650
14GW-3-2500/0.5JJ2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
15GW-3-2500/0.5J2750690/950
(6 Pulse)
2275/
1700
25002840/
2080
880/
1250
2.565002600/32000.1~0.150.25~0.33610/560
16GW-4-3000/0.5J3300690/950
(6 Pulse)
2730/
2040
30003410/
2500
880/
1250
3.25002600/32000.1~0.150.25~0.34610/560
17GW-5-4000/0.5J4400950
(6 Pulse)
2300400033301250550034000.1~0.150.25~0.35600/550
18GW-6-4000/0.5J4400950
(12 Pulse)
2300400033301250550034000.1~0.150.25~0.36600/550
19GW-8-5000/0.5J5000950
(12 Pulse)
34005000420012507~850034000.1~0.150.25~0.38600/550
20GW-10-6000/0.5J6300950
(12 Pulse)
37506000460012508.5~950034000.1~0.150.25~0.310600/550
21GW-12-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.312600-550
22GW-15-8000/0.25J8000950
(12 Pulse)
49008000600012509~10.525034000.1~0.150.25~0.315600-550
23GW-15-10000/0.25J10000950
(24 Pulse)
6500100008000125013~1525034000.1~0.150.25~0.315600-550
24GW-18-12000/0.25J12000950
(24 Pulse)
81601200010000120015~1725034000.1~0.150.25~0.318600-550
25GW-20-12000/0.25J12000950
(24 Pulse)
81601200010000120017~1925034000.1~0.150.25~0.320600-550
26GW-25-14000/0.25J14000950
(24 Pulse)
94601400011600120019~21150~20034000.1~0.150.25~0.325600-550
27GW-30-16000/0.2J16000950
(24 Pulse)
108501600013300120021~23150~20034000.1~0.150.25~0.330600-550
28GW-40-20000/0.2J20000950
(24 Pulse)
135452000016600120025~27150~20034000.1~0.150.25~0.340600-550
29GW-50-22000/0.2J22000950
(24 Pulse)
149322200018300120025~28150~20034000.1~0.150.25~0.350600-550

Note:
(1) GW - means medium frequency induction furnace, - 1 - means induction furnace capacity of 1 ton, - 500 - means furnace rated power of 500 KW, / 1 - means furnace operating frequency of 1000 Hz, / 0.5 - means melting furnace frequency of 500 Hz, - J - means hydraulic tilting furnace (furnace shell is steel shell), - JJ - means mechanical tilting furnace. (the shell of the furnace is aluminum alloy).

(2) The above quoted price is for routine configuration. Other configurations can be added, such as leak alarm, water temperature alarm, furnace switch, cover mechanism, lining ejector and transformer, cooling device (open and close cooling tower, closed cooling tower, plate heat exchanger)

3) If necessary, send technicians to carry out the commissioning: the domestic section is free; the overseas section travel expenses, accommodation and food are borne by the user and each person is subsidized 150 US dollars per day.

4) I quote EX-W at a price including simple packing, including shipping charges to Shanghai port area and all inland charges in China.

V) The above electric furnace voltage levels are 380V, 690V and 950/1000V, and the frequency is 50HZ. If the user equipment requirements are different from the above voltage levels and frequencies, each item needs to be increased by 15000USD.
 
  
  
  
  
  
  
  
  
  
  
  
  
  
hydraulic brake pressure ring water-cooled cable copper pipe short net water-cooled compensator forged copper tile for Submerged arc furnace
hydraulic brake
 pressure ring 
water-cooled cable 
copper pipe short net 
water-cooled compensator
 forged copper tile 
High Quality Hydraulic Drum Brake
Brake mounting dimensions and braking torque parameters meet JB / ZQ4388-1997 standards, technical requirements in line with JB / T6406-2006 standards.
  You can set additional functions zo (see brake additional menu}.
  Conditions of use:
Ambient temperature: -20ºC ~ 50ºC;
surroundings not have flammable, explosive and corrosive gases in the working environment, or should use anti-corrosion products.
air relative humidity less than 90%.
Altitude reference point of use in line with GB755-2000