Three Phase DIN Rail LCD/LED RS-485 Digital Power Meter

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 80 ~ 85

Description
ME631 Three-phase Power Meter


 
Connectivity advantages
MODELME631
Support Extra sensor333mV CT
Rogowski coil
Programmable digital outputAlarm
3 Tariff
I/O function1*relay output
Power85~265V AC/DC
Rogwoski coil specification85mV/kA@50Hz±0.5%


Feature
Specification
ModelME631 
Product component typeMultifunction power meter 
Poles description3PH4W       3PH3W
1PH2W (L-N)  1PH2W(L-L) 1PH3W(L-L-N)
 
Device applicationPower analysis
Tariff meter
 
Input typeExternal CT(333mV only)
External Rogowski coil
 
Display2.0 inch TFT screen display 
Sampling rate 8k samples per second 
Mounting modeClip-on 
Mounting supportDIN rail 
Harmonic52th Max 
Display characteristics
Dimensions (VA)39mm x 32mm
Display resolution220 x 170 dots
Mechanical characteristics
Weight212g
DimensionL*W*D:76*95*71mm


Display
Maximum value measured
ParameterRangeResolution
Voltage0.001V
999.9V
999.9kV
999.9MV
0.1
Current999.9A
999.9kA
0.1
Power999.9kW
999.9MW
0.1
Power factor0.9990.001
THD99.9%0.1%
Energy999.9WH
999.9.KWH
999.9MWH  999.9GWH
0.1
Instantaneous rms Values
VoltageU,UTH2,UTH3,UTH4(Per Phase,AVG)
CurrentI,ITHD2,ITHD3,ITHD4(Per Phase,AVG)
PowerP,FQ,S,PF(Per Phase,SUM)
EnergyEP,EFQ,ES,Freq(Per Phase,SUM)
over 999.9GWh,value reset
UTHD(%)UTHD,THD2,THD3,THD4(Per Phase,AVG)
ITHD(%)ITHD,THD2,THD3,THD4(Per Phase,AVG)
Update rate
Data acquisition rate400ms
Display update rate0.5s
Energy storage interval
( prevent losing energy when power off )
10mis(default)
Calibration
Current Per phase,all
VoltagePer phase,all
Power factorPer phase,all
Energy Reset to "0"  EP,EQ,ES all phase
Record (if order please add -SD in model No.
Record interval1s to 9999s(default 1min)
Record formatcsv
Record capacity1GB(default) record 3.5years in default
Record dataVoltage(V),UTHD(%),Current(A),ITHD(%),Frequency(Hz),PF(power factor),Active Power(KW),Reactive Power(KVar),Apparent Power(KVa),
ActiveEnergy(KWh),Reactive Energy(KVarh),Apparent Energy(KVah)
 
Communication
Transmission modeRS485 port,Half duplex
RS485 link 2 wires
Communication protocolMODBUS RTU
Settings
Communication address1 to 247 (default 1)
Baud rate(communication speed)1200 to 57600 baud (default 9600)
ParityEven(default),Old,None 
Data bit8
Stop bit 1
Certificate
Environmental conditions
Operating temperature-25ºC to +55ºC
Storage temperature-40ºC to +85ºC
Humidity rating5 to 95% RH at 50ºC(non-condensing)
Pullution degree2
Overvoltage categoryIII,for distribution systems up to 277/480VAC
Dielectric withstandAs per IEC61010-1, Doubled insulated front panel display
Altitude3000m Max
IP degree of protectionIP20 conforming to IEC 60629
ColourWhite
Contractual warranty12months
EMC
Electrostatic dischargeLevel IV(IEC61000-4-2)
Immunity to radiated fieldsLevel III (IEC61000-4-3)
Immunity to fast transientsLevel IV (IEC61000-4-4)
Immunity to surgeLevel IV (IEC61000-4-5)
Conducted immunityLevel III (IEC61000-4-6)
Immunity to power frequency magnetic fields0.5mT (IEC61000-4-8)
Conducted and radiated emissionsClass B (EN55022 )
Standard compliance
EN 62052-11,EN61557-12,EN 62053-21,EN 62053-22,EN 62053-23,EN 50470-1,EN 50470-3,
EN 61010-1,EN 61010-2,EN 61010-031



Specification
Measurement accuracy
 
Current 0.5% from 1% to 120%(don't ensure accuracy when <10A)
Rated current 500A(0.5% from 10A to 600A)
3000A(0.5% from 30A to 3600A)
10kA(0.5% from 100A to 12kA)
Rogwoski coil specification85mV/kA@50Hz±0.5%
Voltage0.2% from 100V to 500V(L-L and L-N)
Power factor±0.005 from 10% to 120%
Active/Apparent Power IEC62053-22 Class 0.5
Reactive powerIEC62053-21 Class 2
Frequency0.01% from 45 to 65Hz
Active energy IEC62053-22 Class 0.5s
Reactive energyIEC62053-21 Class 2
Measurement arrange
Measured voltage100V to 500V AC
Frequency range50/60Hz
Input-current characteristics
Primary current rangeAdjustable from 0.1A to 9999A
Measurement input range 1/225mV-333mV
Permissible overload600mV for 10s/hours
Control Power
AC/DC85 to 265V AC/DC, 3W
Output
Digital output 1×digital output(2 ports)(controlled by Modbus)
2.5kVrms insulation
Maximum Switching Power :
10A, 277VAC
10A, 28VDC
Wire diameter for terminals
Connections-terminalsScrew terminals 2.5mm2,interval 5.08mm
Alarm
SettingU and I Each phase
Output formBuzzer,Relay





Product Tag:
Related categories: