Biobase Elisa Processor 8~1000 Pipetting Medical Diagnosis Equipment

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 5999 ~ 12000

Description

Product Description


Auto ELISA Processor BIOBASE 2000

Features

1.1 Robotic hand,2 Pipetting probe, 1μL stepping (1000μLvolumes).
2.Total 23 racks, arbitrary rack can be defined as sample or reagent on the software.
3.4 units 96 well microplates (pipetting,incubator,reading).
4.1 unit independent washer &reader( two 8 nozzle manifolds).

 

 

 

Detailed Photos

 

Product Parameters

 
Model
BIOBASE2000
Sample 
pipetting unit
Sample rack
24 sample tubes/rack, at most 25 racks
Primary sample tubes
11.5-13mm
Pipetting
8μL~1000μL, (10μL) CV<5%
Time to dispense
15 minutes (typical)^100μL of 96 samples to plate from sample tubes or dilution tubes.
Dispensing system
1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000μL continuous flow washing station.
Reagent pipetting unit
Reagent racks
2 reagent tanks(60ml)/ rack, at most 25 racks
QC racks
24 positions/QC rack, at most 25 racks
Pipetting
8μL~1000μL,1μL stepping,
pipetting precision
(100μL )CV≤0.5%
Time to dispense
2 minutes(typical)^100μL of 96 reagents to plate from reagent bottle
Washing unit
Programmable
Yes(options & parameters)
Wash containers
4 wash buffers at 2.0L, with level-sensing
Waste containers
10L with waste full sensor
Washing system
two 8 nozzle manifolds, one to dispense and the other one to aspirate;
Washing residual
<2μl
Reading unit
Reading system
8 independent photometric channels with mono and bichromatic reading capability
Photometric range
0.000 ~3.000 OD
Spectral range
400-700nm
Optical filters
2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
Reading inaccuracy
inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
Incubation unit
Incubators
4 independent units
Programmable
Yes
Temperature range
RT to 45 °C
Temperature accuracy
±0.5ºC
Temperature staility
±0.5ºC
Software unit
Software system
Windows XP or Windows 7 or above, LIS system available, realize two-way data communications
Function application
work list set up, patient reports and result filing; calibration curve ,storage for each carried out test
Data reduction
cut-off (qualitative)
Physical Specification
Power Supply
AC220V+ 10%,50/60Hz,450W
Instrument Dimension
110*72*70cm (L*W*H)
Instrument Weight
100kg
Package Dimension
138*91*98cm(L*W*H)
Total Weight
150kg