Type | ZC-102F | |
Application | Test CT: excitation characteristics, variable ratio, polarity, ratio error and angle error etc. Test PT: excitation characteristics, ratio, polarity, secondary winding resistance, ratio error, etc. | |
Working power supply | Input voltage | 185Vac~250Vac |
Allowable Input Voltage | 85Vac~264Vac | |
Frequency | 50/60Hz | |
Allowable frequency | 45Hz~65Hz | |
Input power | 5000VA | |
Connector | Standard AC socket 60320 | |
Built-in booster | Output range | 0~2500V(220V power) |
0~20A | ||
Volt-ampere characteristic test reference load capability | 1A/2500V | |
2A/1500V | ||
5A/600V | ||
10A/220V | ||
20A/30V | ||
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.5 class Variable Ratio Measurement Accuracy: 0.5 class | |
External booster | Output range | 0~4000V/1A |
Volt-ampere characteristic test reference load capability | 1A/4000V | |
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.5 class Variable Ratio Measurement Accuracy: 0.5 class | |
Up-flow Reactor | Output range | 0~600A |
Volt-ampere characteristic test reference load capability | 800VA | |
Measurement Accuracy | Variable Ratio Measurement Accuracy:<1% | |
Environment condition | Operating temperature | -10ºC~+50ºC |
Storage temperature | -25ºC~+70ºC | |
Relative humidity | 5%~95%,No condensation | |
Physical characteristics | Size | 425×300×290mm3 |
Weight | ≈26kg(not include accessories ) |