Dental Implant Led Light Source For Endoscopy Easy Operation New Wholesale Handheld Finger Pulse Oximeter

Product Description


Model:CMS50D4  Brand:CONTEC



Instructions
non-invasive device intended for the spot-check of oxygen saturation of arterial hemoglobin (SpO2) and the pulse rate of adult and pediatric patients in home and hospital environments (including clinical use in internist/surgery, anesthesia, intensive care ect.). This device is not intended for continuous monitoring.

Major Features
1)SpO2 value display
2)Pulse rate value display, bar graph display
3)Pulse waveform display
4)PI value display
5)The display mode can be changed
6)Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
7)Pulse sound indication and over limit indication

Main performance
1) Display Mode:Color display
2) Screen Resolution:128*64
3) SpO2 Measuring Range:0%~100%, (the resolution is 1%).
  Accuracy:70%~100%:±2% ,Below 70% unspecified.
4) PR Measuring Range:30 bpm~250 bpm, (the resolution is 1 bpm)
  Accuracy:±2 bpm or ±2% (select larger)
5) PI Measuring Range: 0 %~ 20%
  Accuracy:When the PI measure range is 1%~20%,the permission of absolute error is ±1%
           When the PI measure range is 0%~0.9%,the permission of absolute error is ±0.2%
6) Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
7) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
8) Power Consumption:less than 80 mA
9) Voltage: DC 2.6 V - 3.6 V
10) Power Supply:1.5 V (AAA size) alkaline batteries × 2 
11) Safety Type:Interior Battery,BF Type

Accessories
1)One hanging rope;
2)One User Manual.

Physical characteristic
Dimensions:60(L) × 30.5(W) × 32.5 (H) mm
Weight:About 50g (with the batteries))



Main performance
Display ModeColor display
SpO2 Measuring Range0%~100%, (the resolution is 1%).
Screen Resolution128*64
PR Measuring Range30bpm~250bpm, (the resolution is 1bpm)
Accuracy70%~100%: ±2% ,Below 70% unspecified
Accuracy±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding lightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%
Power Consumptionless than 30mA
VoltageDC 2.6V~3.6V
Power Supply1.5V (AAA size) alkaline batteries × 2
Battery working hourThe minimum continually work time is 20 hours, theoretical number is 36 hoursc
Safety TypeInterior Battery, BF Type
 

Detailed Photos



 

Product List

-TELEMEDICINE products

-Pulse oximeter
-Patient Monitoring
-ECG machine(Electrocardiograph)/Holter ECG/Stress test ECG,
-EEG,
-Ultrasound Imaging,Pocket fetal doppler,fetal monitor,
-Blood pressure Monitor(ABPM),
-spirometer
-infusion/syringe Pump
-Digital Stethscope
-In-Vitro Diagnostics
-simulator
-Veterinary products

View more products,click here...

Company Profile











Product Tag:
Related categories:
Scroll to Top