Medical Disposable 5 Depth Adjustable Lancing Device with Ejector

Min.Order: 100
Product origin: Qingdao, Shandong, China
Infringement complaint: complaintComplaint
US$ 0.39 ~ 0.96

Description
Safety Blood Lancing Device, assist diabetic patients to monitor their glucose levels, easily and safely with an adjustable dial,lancing depth can be set to an appropriate level for the individual . Any standard lancet can be used with these devices, to obtain small blood samples for accurate blood glucose, hemoglobin and other blood components testing.
DescriptionColorSpecificationPackage
Blood LancetRed21G100 pes/box 20000 pes/ctn; 200 pes/box 20000 pes/ctn
Light Blue23G
Beige26G
Blue28G
Purple30G

PRINCIPLE AND INTENDED USE:

The lancing device is used with compatible disposable sterile lancets to draw capillary blood from the fingertip, palm (at the base of the thumb) or forearm, for blood glucose testing or other testing utilizing small amounts of blood.

IMPORTANT:

Prior to testing, wipe the test site with an alcohol swab or soapy water. Use warm water to increase blood flow if necessary. Then dry your hands and the test site thoroughly. Make sure there is no cream or lotion on the test site.

WARNING:

1. Keep the Lancing Device clean.
2.
The lancing device is for single patient use. Do not share it with anyone including other family members! Do not use on multiplel patients!
3.
Do not reuse lancet, always use a new, sterile lancet for testing.
4.
Use caution whenever the lancet needle is exposed, especially when removing the used lancet from the device and when disposing the used lancet.


CARE OF THE LANCING DEVICE:

1. Remove the Lancing Device Cap. Wash the Lancing Device Cap in warm, soapy water. Rinse well and allow it to dry thoroughly.
2. Clean the remaining outside of the Lancing Device using a alcohol swap or soft cloth with mild soapy water as required.
3. To disinfect the Lancing Device Cap, use a disinfectant dilution (containing 2000 mg /L of chlorine) and immerse for 30 minutes,l then wash with water and wait until it is dry.(Hospitals should consult their own infection control protocols)
4. The remaining outside of Lancing Device can be disinfected using 75% Isopropyl Alcohol. Carefully dry the lancing device. Do not immerse the lancing device in liquid.


Operation procedure:

1.Twist off the Lancing Device Cap.
2.Insert a new sterile lancet into the Lancet Holder. Push down firmly until it is fully seated.
3.Twist off the Lancet Protective Cap and save the Cap for later use. Replace the Lancing Device Cap.
4.Set the lancing level by twisting the AdjustableTip until the number lines up with the Arrow.To select the best depth:1-2 for soft or thin skin3 for average skin4-5 for thick or calloused skin.

5. Slowly pull back the Cocking Control. You will hear a click, indicating that the Lancing Device is now loaded and ready to use.
6.Hold the Lancing Device firmly against the side-tip of the finger.
Press the Release Button. Set the Lancing Device aside and proceed with your blood glucose test according to your blood glucose meter's directions.
7.After use, twist off the Lancing Device Cap. Push the exposed tip of the lancet into its Protective Cap.
8.Slide the Lancet Ejector forward and disposing the used lancet in an approved container.
Discard the used lancet according to your country's safety regulations. Replace the Lancet Device Cap.