Hydrogen Fuel Cell Voltage Monitor CVM System
N1200 Series Cell Voltage Monitor
 
Product Introduction
N1200 series cell voltage monitor is specially developed by NGI for fuel cell R&D and production. It is with compact size,high integration, high reliability and fast data transmission. N1200 standalone supports up to 200 channels. More channelscan be tested simultaneously under cascade mode. Voltage acquisition ranges are from -5V to +5V, which completelycovers the voltage range of fuel cell. Real-time voltage data of total 200 channels can be uploaded within 50ms by adopting100M Ethernet communication.

Application Fields
Fuel cell voltage monitoring
Battery cell voltage monitoring

Main Features
*Voltage acquisition range: -2.5V~+2.5V, -3V~+3V,-5V~+5V
*Voltage acquisition accuracy : 1mV, 2mV
*High integration, standalone with up to 200 channels
*Fast data transmission, within 50ms for total 200 channels transmission
*100M Ethernet communication
*Easy system integration, supporting standard Modbus protocol, convenient for integration into PLC and other control systems
*Compact size, standard 19-inch 1U, convenient for rack installation

Standalone supporting 200 channels of voltage monitoring
N1200 CVM integrates 200 channels in a 19-inch 1U standard chassis. For more channel testing requirements, multiple sets of N1200 can be used for simultaneous testing, which not only saves space for customers, but also improves convenience.

200 channels data update time 50ms
The ultra-fast sampling speed of N1200 and the fast transmission speed make the time from acquisition to update of 200 channels data up to 50ms.



Voltage acquisition accuracy up to 1mV
N1200 CVM uses a stable detection circuit to measure the voltage of fuel cell with an accuracy of up to ±1mV,enabling real-time high-accuracy voltage detection of single fuel cell. The temperature coefficient is as low as 50ppm/ºC, and the error caused by every ten degrees Celsius does not exceed 0.05%, which enables N1200 to maintain high precision in application.




Exhibitions

Product Line
 
ModelN1200-25N1200-30N1200-50
Channel200CH160CH80CH
Voltage Acquisition
Range-2.5V~+2.5V-3V~+3V-5V~+5V
Accuracy(23±5ºC)1mV1mV2mV
Resolution0.1mV0.1mV0.1mV
Temperature Coefficien(0~40ºC50ppm/ºC
General
Data Update Cycle≤50ms
Connector TypePluggable terminal
InterfaceLAN/CAN
Communication ProtocolModbus protocol
AC InputSingle phase, 100-240V AC, 50/60Hz
Inter-channel Isolation600V
TemperatureOperating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating EnvironmentAltitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net WeightApprox. 3kg
Dimension1U, 44.0(H)*482.0(W)with handle*410.0(D)mm