Model | heatSTAR+6F | heatSTAR+9F | heatSTAR+12F | heatSTAR+15F | heatSTAR+19F | ||
Power Supply / Refrigerant | V/Hz/Ph | 220-240/50/1 - R32 | 380-420/50/3 - R32 | ||||
Max. Heating Capacity (1) | kW | 6.5 | 9.2 | 11.6 | 15.35 | 18.5 | |
C.O.P (1) | W/W | 4.61 | 4.38 | 4.3 | 4.78 | 4.47 | |
Heating Capacity Min./Max.(1) | kW | 3.5 / 6.5 | 4.3/9.2 | 5.5 / 11.6 | 6/15.35 | 9.2/18.5 | |
Heating Power Input Min./Max.(1) | W | 758 / 1410 | 927/2097 | 1107 / 2683 | 1222/3209 | 1834/4142 | |
C.O.P Min./Max.(1) | W/W | 4.5 / 4.7 | 4.38/4.71 | 4.3 / 4.9 | 4.78/5.06 | 4.47/5.01 | |
Max. Heating Capacity(2) | kW | 6 | 8.6 | 11.2 | 14.26 | 18.2 | |
C.O.P (2) | W/W | 3.46 | 3.37 | 3.45 | 3.64 | 3.6 | |
Heating Capacity Min./Max.(2) | kW | 3.15 / 6 | 3.9/8.6 | 4.9 / 11.2 | 5.6/14.26 | 8.5/18.2 | |
Heating power input Min./Max.(2) | W | 943 / 1732 | 1162/2550 | 1401 / 3263 | 1551/3913 | 2248/4998 | |
C.O.P Min./Max.(2) | W/W | 3.34 / 3.56 | 3.37/3.58 | 3.3 / 3.5 | 3.64/3.82 | 3.6/3.82 | |
Max. Cooling Capacity (3) | kW | 7.45 | 9.5 | 9.8 | 18.57 | 22.5 | |
E.E.R (3) | W/W | 4.05 | 4.23 | 3.9 | 3.78 | 3.58 | |
Cooling Capacity Min./Max.(3) | kW | 6.22/7.45 | 6.7/9.5 | 7.2/9.8 | 7.23/18.57 | 8.5/22.5 | |
Cooling Power Input Min./Max.(3) | W | 1400/1863 | 1679/2242 | 1791/2510 | 1334/4917 | 1660/6285 | |
E.E.R Min./Max.(3) | W/W | 4.05/4.45 | 4.0/4.6 | 4.0/3.8 | 3.78/5.42 | 3.58/5.12 | |
Max. Cooling Capacity (4) | kW | 4.5 | 7.2 | 8.5 | 13 | 16 | |
E.E.R (4) | W/W | 2.7 | 2.8 | 2.9 | 2.96 | 2.85 | |
Cooling Capacity Min./Max.(4) | kW | 3.5/4.5 | 4.9/7.2 | 4.9 / 8.5 | 4.46/13 | 5.5/16 | |
Cooling Power Input Min./Max.(4) | W | 1.33/1.68 | 1451/2366 | 1358 / 2987 | 2592/4390 | 2970/5510 | |
E.E.R Min./Max.(4) | W/W | 2.5/2.74 | 2.8/3.1 | 2.6 / 3.5 | 2.96/3.29 | 2.85/3.2 | |
Workable Ambient Temperature Range | ºC | -25~43 | |||||
Min. System Water Temperature (Heating / Cooling) | ºC | 20 / 7 | |||||
Min. Floor Area for installation, operation and storage | m2 | 7 | 17 | 28 | 56 | 58 | |
Min. Area of Pipe-work | m2 | 7 | 17 | 28 | 56 | 58 | |
Max. Operation High Pressure | MPa | 4.2 | |||||
Max. Operation Low Pressure | MPa | 1.2 | |||||
Components | |||||||
Compressor | Type - Quantity/System | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | Twin Rotary - 1 | |
Fan | Quantity | 1 | 1 | 1 | 2 | 2 | |
Airflow | m3/h | 2500 | 3150 | 3150 | 6200 | 7000 | |
Rated power | W | 34 | 45 | 45 | 90 | 120 | |
Noise Level (sound power) | Indoor/Outdoor | dB(A) | 44/52 | 44/53 | 44/52 | 44/59 | 44/61 |
Water Side Heat Exchanger | Type | Plate Heat Exchanger | |||||
Water Pressure Drop | kPa | 26 | 26 | 26 | 26 | 26 | |
Piping Connection | Inch | G1" | G1" | G1" | G1-1/4" | G1-1/4" | |
Hydraulics | |||||||
Allowable Water Flow | Min./Rated./Max. | L/S | 0.21/0.29/0.35 | 0.26/0.43/0.52 | 0.34/0.57/0.68 | 0.43/0.71/0.85 | 0.55/0.92/1.1 |
Dimensions and Weight | |||||||
Net Dimension(L×D×H) | Outdoor Unit | mm | 1010x370x700 | 1165x370x845 | 1165x370x845 | 1085x390x1450 | 1085x390x1450 |
Net Weight | Outdoor Unit | Kg | 65 | 78 | 85 | 120 | 130 |
Q: Do you provide OEM & ODM?
A: Yes. We can design products and make logos, labels, cartons, user manuals etc. according to our customer's demand.