Small Size Isolated 4-20mA Output DC Current Monitoring Sensor Voltage Transmitter

Min.Order: 1
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 14 ~ 15.5

Description
Small Size Isolated 4-20mA Output DC Current Monitoring Sensor Voltage Transmitter 

General characteristic:

Low cost, small size, SIP 12 anti- fire UL94V-0 package
No external component, need not "ZERO"and "G. Adj" adjustment.
Three-port (power/input/output) isolation: 3000VDC
Assistant power: 5VDC/12VDC/15VDC/24VDC
0-75mV/0-2.5V/0-5V/0-10V/0-± 100mV/0-± 5V/0-± 10Vvoltage signal or 0-10mA/0-20mA/4-20mA/0-± 10mA/0-± 20mA current signal isolation and transfer
Temperature range: -45~+85 centigrade
In EMC(electromagnetism disturb) circumstance need adopt shield measure.

Applications:
DC current/voltage signal isolated/transfer/amplifier
No distortion in long distance signal transmission
Analog signal data acquisition
4-20mA(0-20mA)/0-5V signal isolation and transfer
Equipment and sensor signal acquisition
Signal transmit no-distortion
Electric power, distant control, isolated safe bar
4-20mA sensor analog signal transmission
Ground interference control

Specification:
SUNYUAN ISOEM series is electromagnetic isolation mixed IC, it is made of isolated DC/DC converters and electromagnetic isolation signal amplifier, it is ideally suited for no special need about EMC(electromagnetism disturb) Compare to photoelectrical isolation, it can not be used in strong electromagnetism, so clients need adopt shield measures, it can reach 5000VDC insulated. Sunyuan ISO EM series it is very easy to use, no external components are required.
Products style: Weldable to PCB directly and DIN 35 1x2 or DIN35 2x2 Rail-Mounted
0-5V/0-10V/0-75mV/0-2.5V/0-1mA/0-10mA/0-20mA/4-20mAisolated signal of international standard signal input and output
Accuracy grade: 0.1/0.2, Extremely high linearity in whole process(non-linearity<2%), need not "ZERO"and "G. Adj" adjustment...

Step one :  Please confirm the detail model number with our sales , please refer to bellow model selection to confirm which detail model number do you wanna ?
For Example:
Input siganl:0-5VPower supply:24VOutput signal:4-20mAModel number : ISOEM U1-P1-O1
Input signal:0-10VPower supply:24Voutput signal:4-20mAModel number : ISOEM U2-P1-O1
Input signal:0-20mAPower supply:12Voutput signal:0-20mAModel number : ISOEM A3-P2-O2
Input signal:4-20mAPower supply:24VOutput signal:4-20mAModel number : ISOEM A4-P1-O1
Input signal:0-3.3VPower supply:24VOutput signal:4-20mAModel number : ISOEM U8-P1-O1
Input signal:0-100mVPower supply:24VOutput signal:4-20mAModel number : ISOEM U8-P1-O1
etc.....etc....etc...etc....


Step Two : We have 3 different Installation methods , as bellow shows, you can confirm with us which one installation method suitable for you ?

 
Step three : the final model number confirmation:

Pin description for the 3 different installation methods for customers reference:


Other prodcuts:
<0.1%).>
Features:
1. No external power supply required, two-wire signal loop powered output mode.
2. Active 4-20mA signal acquisition, volt. (5-32V) extra-wide range input.
3.High precision within 4-20mA measuring range (0.1, 0.2).
4.4-20mA signal transmission with high linearity(non-linearity error <0.1%).<>
5. Active 4-20mA signal acquisition input, 3KV isolation between input and output.
6. Active signal input, the output can control the active load in current loop.
7. SIP 12Pin small size, UL94V-0standard fire-retardant package.
8. Industrial operating temp. : - 45ºC ~ + 85ºC.
Applications of Two-wire 4-20mA Current Loop Transmitter/Conditioner:
1. Two-wire active load signal matching and controlling.
2.PLC, DCS site analog signal isolation and acquisition.
3. Ground wire current loop isolation and interference.
4. The matching between sensor signals and analog data input and output terminals.
5. Sensor 4-20mA signal isolated acquisition, conditioning and transmission.
6. Analog signal data isolated acquisition and long-distance transmission.
7. Electric meters and instruments, medical equipments.
 
Features:
1. Three-wire, four-wire or two-wire PT100/Cu50 thermal resistance signal input
2. Accuracy, Linearization error grade:0.2(Relative Temperature)
3. Built-in linear processing and long-term compensation circuit
4. Isolation Voltage: 3000VDC   Three port: input/power/output
5. Auxiliary Power Supply:5V, 12V, 15V or 24VDC, etc
6. International standard signal output:4-20mA/0-5V/0-10V etc
7. Small size, low cost, easy use and high reliability
8. Standard DIP 24/SIP12 Pin, UL94V-0 package
9. Industrial temperature range: - 45ºC ~ + 85 ºC
10. Temperature signal isolation, acquisition and transfer
11. Industry site high-precision temperature measure
12 Terminal resistance signal isolation and temperature control
13. Ground interference suppression
14. Temperature sensor signal converter to standard signal
15. Oil temperature measure and Alarm
16. Signal remote without distortion transmission
17. Power monitoring, medical equipment, temperature control isolation barrier

























Product Tag:
Related categories:
Scroll to Top