APF
Most of the widely used loads are nonlinear loads, such as rectifiers, frequency converter, UPS, elevator, air conditioner, energy-saving lamp, copier, household appliances, etc. These nonlinear loads will produce a large number of harmonic currents and inject them into the power grid, which will distort the voltage waveform and do serious harm to the power grid and all back-end users. In addition, impact and fluctuating loads, such as electric arc furnace and welding equipment, will not only produce a large number of high-order harmonics but also cause power quality problems such as voltage fluctuation, flicker, and three-phase imbalance, which seriously affect the use efficiency of power. The active power filter of our company includes two commonly used industrial voltage grades of 400V and 600V, three-phase three-wire and three-phase four-wire systems, and the capacity ranges from 30A to 1500A. It has the characteristics of fast response speed, strong filtering capacity, flexible installation, and convenient expansion, and can meet the needs of different users. In addition, the Vesige active power filter has strong expansion ability, and filters with different capacities expand each other so that users can formulate more flexible harmonic treatment schemes.


 APF Characteristics
1.It can dynamically filter 2-50 harmonics in real-time, and the effective filtering rate can reach 95%
2.The full response time is less than 10ms
3.Better control flicker and voltage fluctuation
4.Unique ripple self-elimination technology, small ripple
5.Multi-function and multi-mode operation mode
6.High stability and reliability
7.Design life 20 years
8.Modular design for easy installation and maintenance


APF Application fields
1.power consumption system in areas with a large harmonic in the power grid, such as factories, enterprises, etc.
2.manufacturers using high-power nonlinear load and impact load (such as air pump, etc.)
3.power consumption systems with high requirements for power grid quality, such as hospitals, etc.
4.power consumption system requiring comprehensive compensation for reactive power, harmonic and three-phase imbalance

400V series APF technical parameters
SpecificationsVAPG04-50DFVAPG04-75DFVAPG04-100DFVAPG04-150DFVAPG04-200DFVAPG04-300DFVAPG04-400DFVAPG04-500DFVAPG04-600DFVAPG04-800DFVAPG04-1000DFVAPG04-1200DF
Rated voltage (VAC)
 
400
Input voltage range (VAC)
 
400 ± 20%
Operating frequency (Hz)
 

50±5%
 
Rated capacity (Kvar)
 
50751001502003004005006006008001200
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200600×800×2200600×800×2200800×800×2200800×800×22001000×800×22001400×800×22001600×800×2200
Wire system
 
Three-phase three lines / three-phase four lines
Primary incoming line modeLower incoming line / upper incoming line/cabinet busbar
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Number of harmonics that can be filtered2 ~ 50 times
Harmonic compensation rate > 95%
Response time
 
10ms
DisplayTFT true color touch screen, real-time voltage, and current data display

Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40 ~ 70 ° C
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. Single incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above APF models may change due to different on-site working conditions or      the actual needs of users
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation;
4. Due to different options, the size of the APF cabinet may change;
5. Single cabinet installation with size less than 1000mm (included).

600V series APF technical parameters
SpecificationsVAPG06-50DFVAPG06-100DFVAPG06-200DFVAPG06-300DFVAPG06-400DFVAPG06-500DFVAPG06-600DFVAPG06-800DFVAPG06-1000DFVAPG06-1200DFVAPG06-1600DFVAPG06-2000DF
Rated voltage (VAC)
 
600
Input voltage range (VAC)
 
600 ± 20%
Operating frequency (Hz)
 

50 ± 5%
 
Rated Current (A)501002003004005006008001000120016002000
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200800×800×2200800×800×22001000×800×22001400×800×22001600×800×22002000×800×22002600×800×2200
Wire system
 
Three-phase three lines
Primary incoming line modeLower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Number of harmonics that can be filtered2 ~ 50 times
Harmonic compensation rate > 95%
Response time
 
10ms
DisplayTFT true color touch screen, real-time voltage, and current data display

Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature -40 ~ 70 ° C
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. Single incoming line mode is divided into forwarding line type and backward line type, which can be selected
2. The product specifications and parameters of the above APF models may change due to different on-site working conditions or      the actual needs of users
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation
4. Due to different options, the size of the APF cabinet may change;
5. Single cabinet installation with size less than 1200mm (included)

SVG

Compared with the traditional SVC device represented by TCR, the regulation speed of the static var generator (SVG) is faster and the operation range is wider. Moreover, after adopting multiple and equal PWM technical measures, the content of carrier frequency harmonics in compensation current is reduced. More importantly, the reactor and capacitor elements used in SVG are much smaller than those used in SVC, which will greatly reduce the volume of the device. VPV series low voltage static var generator (SVG) has such advantages, which represents the development direction of dynamic var compensation device. The PV series SVG developed and produced by our company realizes the comprehensive coverage of power consumption systems and is widely used in different industries and working conditions. It is divided into 200V series, 400V series, 600V series, and high-voltage series according to the user's service voltage level. The modularization of the power unit makes it easy to expand the capacity of the device, and the independence of the module greatly improves the reliability of the whole machine.


SVG Characteristics
1. Modular design is adopted, and each module unit can compensate reactive power and harmonic separately or at the same time

2. Strong ability to control fluctuation and flicker
3. Using PWM interleaving technology, it's own harmonic is very low
4. Fast response speed, less than or equal to 3MS
5. Low power consumption and small floor area
6. Increase the power grid capacity, reduce losses and purify the power grid
7. Design life 20 years
8. Easy installation and commissioning, no wearing parts, and easy maintenance

 SVG Application field

1.Power system requiring comprehensive compensation for reactive power and harmonic
2.Electrolytic industry using special AC voltage
3.Power consumption systems in areas with low power factors, such as factories, enterprises, etc.
4.Manufacturers using high-power nonlinear load and impact load (such as air pump, etc.)
5.Remote areas with poor power consumption, such as rural areas, mountainous areas, wind farms, etc.
6.Power consumption systems with high requirements for power grid quality, such as hospitals, etc.

Technical parameters of 220V series SVG
SpecificationsVPVG02-140DFVPVG02-280DFVPVG02-420DFVPVG02-560DFVPVG02-840DFVPVG02-1120DFVPVG02-1400DFVPVG02-2100DFVPVG02-2800DF
Rated voltage (VAC)
 
220
Input voltage range (VAC)
 
220±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±140±280±420±560±840±1120±1400±2100±2800
Equivalent capacitance (Kvar)
 
21042063084012601680210031504200
Rated current (A)
 
3677351102147022042940367055127350
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200900×800×22001200×800×22001800×800×22002900×800×22003500×800×22005000×800×22006500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique, and users can choose by themselves according to the application situation; 4. Due to different options, the size of the SVG cabinet may change;
5. If the width is less than 1200mm (included), it is a single cabinet installation.


400V series SVG technical parameters
SpecificationsVPVG04-50DFVPVG04-75DFVPVG04-100DFVPVG04-150DFVPVG04-200DFVPVG04-300DFVPVG04-400DFVPVG04-500DFVPVG04-600DFVPVG04-800DFVPVG04-1000DFVPVG04-1200DF
Rated voltage (VAC)
 
400
Input voltage range (VAC)
 
400±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±50±75±100±150±200±300±400±500±600±800±1000±1200
Equivalent capacitance (Kvar)75115150225300450600750900120015001800
Rated current (A)
 
72108144216288432576720864115214401728
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200600×800×2200800×800×22001000×800×22001400×800×22001600×800×2200
Wire system
 
Three-phase three-wire / three-phase four-wire
Secondary incoming line mode
 
Lower incoming line / upper incoming line/cabinet busbar
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB /T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with CB 7251-2005 (GB/T 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different site conditions or actual              needs;
3. The matching relationship in the table is not unique and can be selected according to the application;
4. Due to different options, the size of the SVG cabinet may change;
5. Single cabinet installation with the width less than 1000mm (included)


 600V series SVG technical parameters
SpecificationsVPVG06-200DFVPVG06-300DFVPVG06-600DFVPVG06-900DFVPVG06-1200DFVPVG06-1800DFVPVG06-3000DFVPVG06-6000DFVPVG06-9000DF
Rated voltage (VAC)
 
600
Input voltage range (VAC)
 
600±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±200±300±600±900±1200±1800±3000±6000±9000
Equivalent capacitance (Kvar)
 
3004509001350180027004500900013500
Rated current (A)
 
19228957786611551732288757748661
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
600×800×2200600×800×2200900×800×22001200×800×22001800×800×22003500×800×22006500×800×22009500×800×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Technical parameters of 1140V series SVG
SpecificationsVPVG1-500DFVPVG1-1000DFVPVG1-2000DFVPVG1-3000DFVPVG1-4000DFVPVG1-5000DFVPVG1-6000DFVPVG1-8000DFVPVG1-10000DF
Rated voltage (VAC)
 
1140
Input voltage range (VAC)
 
1140±20%
Operating frequency (Hz)
 
50±5%
Rated capacity (Kvar)
 
±500±1000±2000±3000±4000±5000±6000±8000±10000
Equivalent capacitance (Kvar)
 
7501500300045006000750090001200010500
Rated current (A)
 
2535061013152020262532303940525065
Overload current multiple
 
1.2
Overall dimension / M (WxDxH)
 
900×900×22001200×900×22002400×900×22003600×900×22004800×900×22006000×900×22007200×900×22009600×900×220012000×2200
Wire system
 
Three-phase three-wire
Secondary incoming line mode
 
Lower incoming line
Operating ambient temperature (ºC)
 
-25 ~ + 45 ºC (derating is required above 40 ºC)
Operating ambient humidity (%)
 
< 95% no condensation
Cooling mode
 
Forced air cooling
Degree of protection
 
IP21/IP20
Working altitude
 
0 ~ 3000m (> 2000m, need to reduce capacity)
Reactive power regulation range
 
Continuously adjustable from rated capacitive reactive power to rated inductive reactive power
harmonic
 
Meet the requirements of power quality and harmonics in the public power grid (GB/T 14549-93)
response time
 
3ms
display
 
TFT true color touch screen, real-time voltage, and current data display
Intelligent communication
 
TCP/IP GPRS Modbus
Storage, transportation, temperature-40~70ºCC
Reliability and life
 
Design life 20 years
electromagnetic compatibilityComply with GB 7251-2005 (GB 7261-2000)

Remarks:
1. The unit incoming line mode is divided into forwarding line type and backward line type, which can be selected;
2. The product specifications and parameters of the above SVG models may change due to different on-site working conditions or      actual needs of users;
3. The matching relationship in the table is not unique. Users can choose by themselves according to the application conditions.
4. Due to different options, the size of the SVG cabinet may change;
5. Single-phase installation with a width less than 1200mm (included).


International Standards and specifications
  • Standard voltage level (3 / 3.3 / 4.16 / 6 / 6.6 / 10 / 11KV)
  • Global standards ISO
  • Environmental requirements (RoHS index, limiting the use of certain hazardous substances in electronic and electrical equipment)
  • GB/T 19001-2016 idt ISO9001: 2015
    ISO 45001:2018
    GB/T 24001 -2016 idt ISO14001: 2015
    AAA credit rating
    Test standards:
    EN IEC 61800-3: 2018
    EN 61000-3-12: 2011
    EN 61000-3-11: 2000



Company Profile


Other products we manufacture

 
Application fields


FAQ:
Q 1: Are you a trading company or a manufacturer?
We are a factory.

Q 2: How long is your lead time?
It depends on the technical solution you need, but it usually takes about 40~60 days. For more specific information, please feel free to ask us.

Q3: Do you provide samples? Is it free or extra?
Yes, we provide samples, and we charge sample fee and freight.

Q4:How to ensure product quality?
We strictly follow the ISO9001 quality management system, and the products will not leave the factory until they pass the quality inspection and test.

PS:
If you need more detailed information, accurate quotation and delivery date, please feel free to contact us.


Product Tag:
Related categories:
Scroll to Top