100KW 500RPM  PMG Hydraulic permanent magnet generatorCharacteristics

1. Optimum aerodynamic shape design: high efficiency, low noise.

2. Centrifugal pitch controlled mechanism: 3m/s low wind speed startup; 3-12m/s wind speed, following wind rotor rotate speed to adjust blade angle at optimum TSR, run in high efficiency; over rated wind speed, wind rotor never goes to over speed and has stable control; 3-35m/s wind speed, wind turbine can run smoothly.

3. Direct drive permanent magnet generator, low startup resistance moment, constant running ability of over loading 1.5 times, maintenance free for more than 30000 hour. 

4. Safety control: has aerodynamic brake, electric magnet brake, mechanical brake and manual stop mechanism.

5. Sealed slip ring, no cable twist;

6. Streamline design. 

7. Long acting anticorrosive treats, no corrosion in 15years. 
 

Detailed Photos



Product Parameters



On grid wind turbine controllerWGMC50K380WGMC100K380WGMC200K380
Wind turbine input
Power50KW100KW200KW
Max. Control power / current100KW/200A200KW/400A400KW/800A
Rated voltage of wind turbine (AC)380V/400V380V/400V380V/400V
Input voltage rangeAC0-600V0-600V0-600V
DC0-900V0-900V0-900V
Braking voltage (DC)Default550V±1%550V±1%550V±1%
Set range530-560V530-560V530-560V
Braking current (DC)Default150A300A600A
Set range0-150A0-300A0-600A
Braking timeDefault10-20 min
Set range0-5000 min
* Generator overspeed controlDefault >300 rpm/min
Set range0-1000 rpm/min
* Over wind speed controlDefault 14 m/s
Set range0-45 m/s
Manual controlManual brake , *remote control brake (with communication function)
Automatic control functionDump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake,
* electromagnetic brake
DC output parameters
Output voltage range (DC)0-550V0-550V0-550V
Constant voltage (DC)Default520V±1%520V±1%520V±1%
Set range510-540V510-540V510-540V
Constant current (DC)Default120A 240A480A
Set range0-120A0-240A0-480A
On grid wind turbine inverterDMWG50KDMWG100KDMWG200K
Rated output power (AC)50KW100KW200KW
Max. Output power (AC)55KW110KW220KW
Input voltage rang (DC)0-800V0-800V0-800V
MPPT Voltage range (DC)(DC)150V-700V150V-700V150V-700V
Max. Input current (DC)114.6A229A458.3A
Rated current104A208A416.7A
THD Current harmonic <3%(at rated power)
Power factor>0.99
Max. efficiency96%
Allowable grid voltage range (AC)220V/380V/440V/480V (Three-phase)±20%
Allowable grid frequency range50Hz/60Hz±10%
Automatic operation conditionsDC input and power grid meet the requirements, and the inverter operates automatically
Restart time after power failure2min(Adjustable)
General parameters
Function Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Automatic protectionControl part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
DisplayTouch screen, LCD
Monitoring contentWind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Protection levelIP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)
EnvironmentOperating amb. Temp. & Hum  -30-60°C,<90% no condensation
Noise (1m)<40dB
Refrigeration modeForced air cooling
 
Controller size / weight500*500*900mm  56kg600*500*1200mm   107kg950*550*1700mm   150kg
Dump load size / weight920*770*380mm  80kg920*770*380mm*2  150kg  923*739*510mm*4  280kg
Inverter size / weight750*600*1320mm  340kg1460*860*1820mm  1.4t1460*860*1820mm  1.6t
        
 
On grid wind turbine controllerWGMC10K380WGMC20K380WGMC30K380
Wind turbine input
Power10KW20KW30KW
Max. Control power / current20KW/40A40KW/80A60KW/120A
Rated voltage of wind turbine (AC)380V/400V380V/400V380V/400V
Input voltage rangeAC0-600V0-600V0-600V
DC0-900V0-900V0-900V
Braking voltage (DC)Default550V±1%550V±1%550V±1%
Set range530-560V530-560V530-560V
Braking current (DC)Default30A60A90A
Set range0-30A0-60A0-90A
Braking timeDefault10-20 min
Set range0-5000 min
* Generator overspeed controlDefault >300 rpm/min
Set range0-1000 rpm/min
* Over wind speed controlDefault 14 m/s
Set range0-45 m/s
Manual controlManual brake, *remote control brake (with communication function)
Automatic control functionDump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake,
* electromagnetic brake
* PV. Input
Rated power (increased)5KWp5KWp5KWp
Working voltage (DC)550V / 660V550V / 660V550V / 660V
DC output parameters
Output voltage range (DC)0-550V0-550V0-550V
Constant voltage (DC)Default520V±1%520V±1%520V±1%
Set range510-540V510-540V510-540V
Constant current (DC)Default24A 48A72A
Set range0-24A0-48A0-72A
On grid wind turbine inverterDMWG10KTLDMWG20KTLDMWG30KTL
Rated output power (AC)10KW20KW30KW
Max. Output power (AC)11KW22KW33KW
Input voltage rang (DC)0-800V0-800V0-800V
MPPT Voltage range (DC)(DC)150V-700V150V-700V150V-700V
Max. Input current (DC)2.4A44.9A67.3A
Rated current20.4A40.8A61.2A
THD Current harmonic <3%(at rated power)
Power factor>0.99
Max. efficiency98%
Allowable grid voltage range (AC)220V/380V/440V/480V (Three-phase)±20%
Allowable grid frequency range50Hz/60Hz±10%
Automatic operation conditionsDC input and power grid meet the requirements, and the inverter operates automatically
Restart time after power failure2min(Adjustable)
General parameters
Function Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting
Automatic protectionControl part: Over voltage protection, over current protection, reverse connection protection, lightning arrester
Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc
DisplayTouch screen, LCD
Monitoring contentWind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed
Protection levelIP20(Indoor)IP65 (Outdoors)
Telematics RS485/USB/GPRS/WIFI/Ethernet (optional)
EnvironmentOperating amb. Temp. & Hum  -30-60°C,<90% no condensation
Noise (1m)<40dB
Refrigeration modeForced air cooling
 
Controller size / weight400*230*550mm  23kg500*230*620mm   35kg500*230*620mm   38kg
Dump load size / weight690*450*530mm  36kg980*880*540mm   70kg980*880*540mm   70kg
Inverter size / weight690*275*770mm  42kg690*275*770mm   58kg690*275*770mm   65kg
       

*Above parameter only for reference. Could be custom made to user specifications.
 