Low Voltage Power Inverter 120% overload

Min.Order: 1
Product origin: Shanghai, China
Infringement complaint: complaintComplaint
US$ 190

Description
VFD   AS180 Series VFD

AS180 Series VFD is an universal VFD desinged for the industry market. The product was adopted with the Germany technology, made in China, and combined with the characters of domestic applicationm, further strengthening the product reliablity and design for customer and the industry, with excellent performance of V/F control to perfectly satisfy a variety of light load driven application requirements.

Feature and Advantages
1. 
High -efficient & energy saving operation

2. Fast Dynamic Response
Advanced motor control can also quickly response to load change without PG Card.
3. Smooth tracking start
At any time, smooth start can be perfectly achieved without impacting the rotating motor.
4. Powerful grid adaptability
Automatic voltage adjustment function: when the grid voltage changes, the output voltage can be automatically kept constant. In the case of sudden loss of electricity, unique non-blackout function can keep VFD running.
 5. Stable operation with low frequency and high torque.
Dynamic calcultion of IGBT internal temperature ensures that the IGBT module operates with the temperture limits, improving reliablity of the module.
6. Positive-reverse switch
When positive-reserve motor switch to the zero-speed, the phase of current has no change or oscillation, and speed has no ripple.
7. Papid acceleration
0.1s full load acclleration with fast torque response and low speed overshoot.
8. IGBT temperature protection curve
Dynamic calculation of IGBT internal temperature ensures that the IGBT module operates within the temperature limites, improving railiability of the module.


Intimate application function

* PID control dedicated menu to set PID parameters, calculate inside the VFD, without independent external regulator option. 
* DC braking before operation: when the rotating direction of motor during free sliding is uncertain, DC braking automatically stop the motor before starting.
* For the square torque load of fan and water pump, high performance excitation control can make the motor run at the optimal efficiency point and achieve optimal energy saving effect.
Product Parameters
Power inputInput voltage380-460V
Input frequency45-65Hz
Accepting voltage changeVoltage unbalance <3%
Voltage dropWhen the 3 phase AC380-460V, input voltage <AC300V, low voltage protection was implemented after 15ms.
Power outputVoltage0VAC ~ input voltage
Overload gradeStable running 40ºC,heavy load 150%, 1min
Efficiency (full load)0.94
Output frequency accuracy±0.01% (digital command -10~+45ºC); ±0.1% (analog command 25±10ºC);
Digital input/outputOptical coupling isolation input7 channels, 24V high and low level can be set, input function can be defined
Open collector output2 channels, output function can be defined
Relay output2 channels, normally open contacts, contact capacity: inductive, 1.5A/250VAC, output function can be defined, 2 channels, dual normally open/closed contacts, contact capacity: resistive, 4.5A/250VAC or 4.5A/30VDC; inductive: 0.4A/250VAC or 0.4A/30VDC, output function can be defined
Analog input/outputAnalog voltage input2 channels, accuracy 0.1%; voltage -10V ~ +10VDC or current 0~20mA optional signal
Analog voltage output2 channels, accuracy 0.1%; voltage -10V ~ +10VDC or current 0~20mA optional signal
Control characteristicsCarrier frequency1.1-8KHz; carrier frequency can be adjusted automatically according to load characters
Frequency setting resolution0.01Hz (digital command), ±0.06HZ/120Hz (analog command 11 bit + no signal)
Running command channelGiven operation panel, given control terminal, given communication
Frequency given channelGive operation panel, given digital quantity/analog quantity, given communication, given performance function.
Torque improvedAutomatic torque improved, manual torque improved.
V/F curveUser defined V/F curves, linear V/F curves, and three reduced torque characteristic curves
Automatic voltage adjustment (AVR)The duty ratio of output PWM signal is adjusted automatically based on the fluctuation of bus voltage, to reduce the influence of grid voltage fluctuation on output voltage fluctuation.
Electricity loss and keep running processIn the case of instantaneous power off, achieve uninterrupted operation through bus voltage control
Direct current braking capabilityBrake current: 0.0~120.0% rated current
Characteristic functionParameters copyThe standard operation panel can upload and download parameters and indicate copy process
Process PIDUsed for closed - loop control of process quantities
Common DC busAll series can achieve the power supply of common DC bus for multiple VFD.
Motor protectionRotor block, motor overload, speed limitation
VFD protectionOutput current limited, VFD overload, IGBT overload, under voltage / over voltage of input power, under voltage / over voltage of DC bus, IGBT over heating, power faulty, analog input signal loss (loss speed reference), communication abnormality, self-tuning faulty.
Environment conditionOperation placeInstalled vertically in a well-ventilated electrical control cabinet. Horizontal or other installation is not allowed. Cooling medium is air. Installed in environment without direct sunlight, dust, corrosive gas, flammable gas, oil mist, steam, or water.
Environment temperature-10 ~ +40 ºC
Used in diminished temperature>40 ºC, a rise of 1 ºC, rated output current is reduced by 2%, the highest temperature is 50ºC
Altitude<1000m
Used in diminished height>1000m, a rise of 1000m, rated output current is reduced by 1% (up to 3000m)
Environment humidity5 ~95%, without condensation
Vibration (transport)2  f < 9Hz, 3.5 mm; 9 f < 200Hz, 10m/s², 200 f < 500Hz, 15m/s²
Vibration (installation)2  f < 9Hz, 0.3 mm; 9 f < 200Hz, 1m/s²
Storage temperature-40 ~ +70 ºC
Protection gradeIP20
Control panelTypeMovable
Length1m, 3m
ConnectorRJ45
LCD text display4 row
LED display5 bit
Visible LED indicator4 pcs
key9 pcs
OthersCooling wayForce air cooling
Installation modeInstalled in cabinet with wall-mounted
CertificateCE


Technical Table

Stable running 40ºC, heavy duty loadingDimension
VFD Model
AS180
Rated input current (A)Rated output current (A)Adaptive motor
(Kw)
Overload 120% (1min)
Output current (A)
4T07P516157.518A1
4T001121201124A2
4T011530.5291534.8
4T18P5383618.543.2A3
4T012246442252.8
4T003059563067.2
4T003775723786.4A4
4T0045949045108
4T005511511055132A5
4T007515414875177.6
4T009018317690211.2A6
4T0110216208110249.6A7
4T0132261252132302.4
4T0160306296160355.2A8
4T0185367356185427.2
4T0200402390200468
4T0220427415220498
4T0250481468250561.6
4T0280533520280624A9
4T0315614600315720
4T0355664650355780
4T0400755740400888

Dimension Table
SpecificationHeight(mm)Width (mm)Depth (mm)Weight (kg)
A13001601624.5
A23792221828
A341423218210.3
A453033028829.5
A561033031038
A675043035079.5
A780043035081
A8880500350112.5
A91030630370170
A101189852431280
A111359852431310
Production line

R&D Center