IEC 60068-2-1 | Test A: Low Temperature Test |
IEC 60068-2-2 | Test B: High Temperature Test |
MIL-STD-810D | High Temperature Test |
MIL-STD-810D | Low Temperature Test |
MIL-STD.202F | High Temperature Life Test |
Model | ET Series | ||||
ET-150 | ET-225 | ET-408 | ET-800 | ET-1000 | |
Volume(L) | 150L | 225L | 408L | 800L | 1000L |
Interior size W*H*D(mm) | 600 | 700 | 700 | 1000 | 1000 |
600 | 700 | 750 | 1000 | 1000 | |
460 | 480 | 800 | 800 | 1000 | |
Temp. range | R:-20ºC~ +180ºC L:-40ºC~ +180ºC S:-72ºC~ +180ºC | ||||
Temp. uniformity | ≤±1.5ºC | ||||
Temp. fluctuation | ±0.5ºC | ||||
Temp. deviation | ≤±2.0ºC | ||||
Heating up rate | 3ºC/min(average) (non-linear no-load) | ||||
Cooling rate | 1ºC/min(average) (non-linear no-load) | ||||
Humidity range | 10%~95/98%R H | ||||
Noise | <=75dB 1 meter distance from the door | ||||
Chamber Structure | Interior material:Stainless steel plate(SUS 304) | ||||
Exterior material:Baked painting steel or stainless steel(SUS304) | |||||
Insulation material:Rigid polyurethane Foam + glass fiber wool | |||||
Controller | Panel:KOMEG 7 inch touch screen controller. KM-5166 cooling output version | ||||
Balanced Temperature & Humidity Control (BTHC)System+PID | |||||
Explosion Proof Fire Suppression System | Spray device:The sprinkler device is built in the top of the inner box test area. When the battery surface temperature is much higher than the predetermined temperature value, the battery pack smokes or catches fire, the sprinkler device will automatically open, and the water pressure can be adjusted from 0.4-0.6MPa. | ||||
Gas monitor:Detect by continuously drawing air samples in the box. When the generated H2, CO, CHx reaches a certain concentration or set value, the gas monitoring system will activate the sound and light alarm and interrupt the test and equipment. | |||||
Pressure relief vent:The pressure relief port is located at the top. When the pressure in the equipment or pipeline exceeds the pressure of the safety valve, the pressure relief is automatically opened. | |||||
CO2 fire extinguisher:Automatic fire extinguishing and automatic shutdown of the machine to protect the equipment from burning | |||||
Electric smoke exhaust system:When the test sample produces harmful gas, ventilate and exhaust internally | |||||
Network Connection | Can be connected to Ethernet via professional software, remote control & assistance function and data collection can be achieved through network, multiple machine can be controlled simultaneously | ||||
Environment Condition | 1.Ambient Temperature: 5ºC-35ºC; 2.Humidity: No higher than 85%R.H 3.Air pressure:80kPa~106kPa 4.Flat and no vibration floor; 5.Good air circulation, no direct sunshine or other direct heat resource radiation; | ||||
Standard accessory | Cable port(Φ50mm)*2; 2pcs stainless steel loading trays, 30kg load/tray;Window lights; Mobile Casters with foot cups;Three-color light*1 | ||||
Safety device | A. Heater protection switch if no water B. Humidifier protection switch if no water C. Heater over-current circuit breaker D. Humidifier over-current circuit breaker E. Circulating fan over-current overload protection F. Compressor high voltage protection switch G. Compressor overheat protection switch H. Compressor over-current protection switch I. Over-voltage under-phase protection switch J. Circuit Breakers K. Leakage switch L. Low humidifier protection M. Water tank low water level warning Controller noise isolation protection O. Zero-crossing gate fluid power controller | ||||
Power | AC 380V±10% 50Hz ,3 phase 4 wires +Ground Wires | ||||
Note: 1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available |
Category | Item | Specifications and features |
Performance | Temperature range | -40°C to +100°C |
Temperature uniformity | ±0.5°C (deviation from temperature setting for central air temperature (total 6 points) for each battery installation area) | |
Allowable heat load | 500 W (at -20°C with air temperature control) | |
Dimensions | Inside dimensions (W × H × D mm) | 1000 ×1000 × 1000 (excluding protrusions) |
Outside dimensions (W × H × D mm) | 1200 × 1715 × 1850 (including protrusions) | |
Safety Devices | Pressure release vent | φ100mm |
Options | Specimen temperature control | Applicable temperature range: -20°C to +60°C Allowable heat load: Supports number of specimens and usage temperature range |
Relay module | Supports no-wiring inside of test area with test chamber rear pass-through method (Standard: φ 100 cable port × 3) | |
Rear power supply storage box | Store various charge-discharge power supply devices (ESPEC or other manufacturers) and reduces installation space | |
Rear power supply storage stand | ||
CO2 fire extinguisher | Automatically extinguishes fire after detecting heat or smoke at thermal runaway and stops operation, linkable to intake/exhaust damper | |
Smoke detector | Uses optical spot detector for efficient detection of smoke during thermal runaway | |
CO/H2 gas detector | Pump suction type that collects gas generated from battery, 2-stage alert, linkable to intake/exhaust damper | |
Intake/exhaust damper | Supports forced ventilation of gas inside of the chamber after CO2 fire extinguisher spray, interlock to gas detector |
Our Process Flow
Pre-sale Service:
Provide test solution
Send specification and quotation
24-hour Online contact
Free software upgrades
Replacement parts
Assistance via phone or internet
On-site diagnosis and repair/online diagnosis and repair
Q:Are your company a trading one or a factory?
A:Factory + trade (integration).More than 30 years focusing on environmental test instruments field.