Portable Gas Chromatograph Price Chromatography

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 4500 ~ 12900

Description
Product Description

Gas Chromatography

DW-GC1290  

Product Description

 

DescriptionEPC(electronic pneumatic control)
 7 inch touch screen display
Sample Introduction Systemsample injector and evaporation chamber
Column OvenTemperature rangeAmbient temperature +7ºC ~ 420ºC  (in 1ºC increment)
Temperature accuracy ± 0.02ºC
Cooling time350ºC~100ºC≤3min, 400ºC~50ºC in 8-10 min at 25ºC ambient
Programmed temperature setting0.1ºC~80ºC/min (in 1ºC increment)
Program ramps20 ramps in total (99 ramps available with control workstation)
Size (L*W*H)284*280*241mm(inside)340*345*281mm(outside)
Flame Ionization Detector 
(FID)
Detection limit≤8×10-12g/s (n-hexadecane)
Drift≤1.5×10-13A/h
Noise≤3×10-14A
Linearity range≥106
Flame Photometric Detector
(FPD)
Detection limit≤8×10-13g/s(P) ; ≤8×10-11g/s(S)
Drift≤2×10-11A/30min
Baseline noise≤5×10-12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit≤5×10-12g/s(N) (Azobenzene)
          ≤5×10-13g/s(P)  (Malathion)
Features:   
*Control system: designed for monitoring and controlling the instrument via the computer.
*Column Compartment/oven with superior thermal performance, multistage (20 ramps) programmed temperature control function. (supported by "control system")
*Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
*Column oven supports quick heat-up and rapid cool-down with automated back-door opening.
*Flexible sample introduction system: 2 sample injectors could be installed and operated simultaneously with independent temperature control.
*High sensibility and stability detector.
*2 independent and analog signals output.
*M6 software, compatible with GLP-21 CFR Part11 requirements and regulations. (electronic records and signatures)

Electronic pneumatics control system

Flow rate: 200ml/min (N2), 1000ml/min (He)
Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35%
Split ratio: 0-5000(He), 0-1000(N2)
Inlet temperature: 0-420ºC
 
Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ FPD/ NPD
 

 