Ngi N6900 Programmable DC Electronic Load, 1 Channel, 120 V/120 a, 3000 W

Min.Order: 1
Product origin: Changsha, Hunan, China
Infringement complaint: complaintComplaint
US$ 1000 ~ 100000

Description
NGI N6900 Programmable DC Electronic Load,1 Channel,120 V/120 A, 3000 W
N6900 Series Distributed High Power DC Electronic Load
 
Product Introduction
N6900 series is developed based on NGI's years of experience in testing for power supply, battery, generator and supercapacitor. It is with high accuracy, high reliability and high cost performance.

According to the features of high voltage & power DC electronic loads with complex structures, harsh operating environments, high reliability requirements, and inconvenient maintenance, NGI has made a number of optimization based on the international advanced technology.

Application Fields
1.Generator
2.Charging station
3.Industrial/server power supply
4.Communication power supply
5.Battery pack
6.Capacitor module
7.High current relay
8.Energy storage system

Main Features
*Power range: 1-50kW
*Voltage range: 120V/600V/1000V/1200V, customization available
*Multiple protection: OCP, OVP, OTP, OPP and reverse polarity warning
*Comprehensive MOS protection to avoid blow-up
*Operation modes: CC/CV/CR/CP
*Charging & discharging control function, convenient for battery and super capacitor test
*Built-in DCIR test function(Optional)
*Easy power expansion by increasing power modules
*Analog programming interface(APG), current monitoring interface, and remote/local trigger function
*CR/CP function supported by hardware
*Short-circuit simulation
*Transient over-power loading capability
*High power density, minimizing space occupation
*Convenient OCP test
*Dynamic mode up to 20kHz, editable rise and fall slew rate
*Editable Von/Voff, reducing test accidents
*LCD screen for data display Intelligent fan control
*Built-in auto test function
*Standard 19-inch 3U, available for rack installation
*Distributed design and flexible power modules
*Multiple communication interfaces: LAN/CAN/RS232/GPIB(optional)

High reliability design
N6900 series has a comprehensive MOS protection circuit. No matter how much MOS is damaged, it will not cause short-circuit between the positive and negative polarity or the positive polarity and the control circuit. The damage of some MOSs does not accelerate the damage of others, which can be used continuously.
By distributed design, it is easy to replace or add power modules and is convenient for maintenance and power expansion.
N6900 is designed with power limit circuit and has fast response, which can prevent the load from being damaged due to over power.
N6900 adopts shielding technology, which has wide adaptability to harsh test environment, and improves the anti-interference ability.

Short-circuit simulation
N6900 series supports two modes for short circuit: manual and lock.

Manual: N6900 will be short-circuited when Short button is pressed. It will stop short-circuiting when button is released. Manual mode is suitable for debugging or R&D, avoiding measurement accidents due to misoperation.
Lock: N6900 will keep short-circuiting when Short button is pressed. It will stop short-circuiting when the button is pressed again. Lock mode is suitable for long-time short-circuit test.

Auto test function
The auto test can be used to simulate waveform. This function can improve the test efficiency and can be achieved by SEQ function on the menu. Up to 100 sequence files editing is supported. Each file can support 50 steps.

OCP( over current protection) test
During OCP test, N6900 will load under CC mode and check whether the DUT voltage is lower than cut-off voltage. If lower, N6900 will record the present loading current as the test result and shut the input to stop the test. If the DUT voltage is higher than cut-off voltage, N6900 will increase the loading current until the DUT voltage is lower than cut-off voltage or it reaches the Max. loading current.

Remote sense to improve measurement accuracy
Remote sense is also know as four-wire sense. When N6900 is working, it will cause a voltage drop in the leads between the DUT and terminals of N6900, which will affect the voltage measurement accuracy of the load.
When working under CV, CR and CP modes, to ensure accurate measurement, it is recommended to use remote sense. During remote sensing, terminals S+ and S- are directly connected to the output of the DUT, eliminating the voltage drop in the leads.

Charge& discharge test
Users can set different conditions on the front panel to meet their test demands. For example, when battery voltage is lower than initial voltage, N6900 internal counter will start counting. The counter will stop working until the battery voltage drops to cut-off voltage.
 
Exhibitions
 

For more specifications, please contact us.
ModelN6903-120-300N6903-120-120N6903-600-120N6903-600-30
Voltage120V120V600V600V
Current300A120A120A30A
Power3000W
Min. Operating Voltage2V@30A2V@300A2V@12A2V@120A4.5V@12A4.5V@120A4.5V@3A4.5V@30A
CC Mode
Range0-30A0-300A0-12A0-120A0-12A0-120A0-3A0-30A
Setting Resolution0.1mA1mA0.1mA1mA0.1mA1mA0.1mA1mA
Setting Accuracy
(23±5ºC)
0.1%+0.1%F.S.
CV Mode
Range0-12V0-120V0-12V0-120V0-60V0-600V0-60V0-600V
Setting Resolution0.1mV1mV0.1mV1mV1mV10mV1mV10mV
Setting Accuracy
(23±5ºC)
0.05%+0.05%F.S.
CP Mode
Range0-3000W
Setting Resolution0.1W
Setting Accuracy
(23±5ºC)
0.5%+1%F.S.
CR Mode
Range0.01Ω~40Ω0.2Ω~400Ω0.02Ω~100Ω0.4Ω~1000Ω0.1Ω~500Ω1.9Ω~5000Ω0.38Ω~2000Ω7.5Ω~20000Ω
Setting Resolution16bits
Setting Accuracy
(23±5ºC)
0.35%+78.1mS0.35%+7.81mS0.35%+31.2mS0.35%+3.12mS0.35%+6.25mS0.35%+0.625mS0.35%+1.5mS0.35%+0.15mS
Slew Rate
Current5-300A/ms300-15000A/ms2-120A/ms120-6000A/ms2-120A/ms120-6000A/ms0.5-30A/ms30-1500A/ms
Voltage1.0-50V/ms50-500V/ms1.0-50V/ms50-500V/ms5.0-250V/ms250-2500V/ms5.0-250V/ms250-2500V/ms
Power5-300A/ms300-15000A/ms2-120A/ms120-6000A/ms2-120A/ms120-6000A/ms0.5-30A/ms30-1500A/ms
Resistance5-300A/ms300-15000A/ms2-120A/ms120-6000A/ms2-120A/ms120-6000A/ms0.5-30A/ms30-1500A/ms
Accuracy (23±5ºC)(1+35%)* Setting value
Voltage Measurement
Range0-12V0-120V0-12V0-120V0-60V0-600V0-60V0-600V
Readback
Accuracy (23±5ºC)
0.05%+0.05%F.S.
Current Measurement
Range0-30A0-300A0-12A0-120A0-12A0-120A0-3A0-30A
Readback
Accuracy (23±5ºC)
0.1%+0.1%F.S.
Power Measurement
Range0-3000W
Readback
Accuracy (23±5ºC)
0.5%+1%F.S.
Dynamic Mode
T1&T20.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms
Resolution1μs1ms1μs1ms1μs1ms1μs1ms
Accuracy (23±5ºC)1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm
Others
InterfaceLAN/RS232/CAN
AC InputSingle phase, 220V AC±10%, frequency 47Hz~63Hz
TemperatureOperating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating EnvironmentAltitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net WeightApprox. 28kg
Dimension3U, 132.5(H)*482.0(W)*612.0(D)mm
 
ModelN6903-1000-90N6903-1000-30N6903-1200-90N6903-1200-30
Voltage1000V1000V1200V1200V
Current90A30A90A30A
Power3000W
Min. Operating
Voltage
5V@9A5V@90A5V@3A5V@30A5V@9A5V@90A5V@3A5V@30A
CC Mode
Range0-9A0-90A0-3A0-30A0-9A0-90A0-3A0-30A
Setting Resolution0.1mA1mA0.1mA1mA0.1mA1mA0.1mA1mA
Setting Accuracy
(23±5ºC)
0.1%+0.1%F.S.
CV Mode
Range0-100V0-1000V0-100V0-1000V0-120V0-1200V0-120V0-1200V
Setting Resolution1mV10mV1mV10mV1mV10mV1mV10mV
Setting Accuracy
(23±5ºC)
0.05%+0.05%F.S.
CP Mode
Range0-3000W
Setting Resolution0.1W
Setting Accuracy
(23±5ºC)
0.5%+1%F.S.
CR Mode
Range0.21Ω-1111Ω4.2Ω-11111Ω0.62Ω-3333Ω12.4Ω-33333Ω0.25Ω-1333Ω5Ω-13333Ω0.75Ω-4000Ω15Ω-40000Ω
Setting Resolution16bits
Setting Accuracy
(23±5ºC)
0.35%+2.8mS0.35%+0.28mS0.35%+0.9mS0.35%+0.09mS0.35%+2.3mS0.35%+0.23mS0.35%+0.7mS0.35%+0.07mS
Slew Rate
Current1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms
Voltage8-400V/ms400-4000V/ms8-400V/ms400-4000V/ms8-400V/ms400-4000V/ms8-400V/ms400-4000V/ms
Power1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms
Resistance1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms1.5-90A/ms90-4500A/ms0.5-30A/ms30-1500A/ms
Accuracy (23±5ºC)(1+35%)* Setting value
Voltage Measurement
Range0-100V0-1000V0-100V0-1000V0-120V0-1200V0-120V0-1200V
Readback
Accuracy (23±5ºC)
0.05%+0.05%F.S.
Current Measurement
Range0-9A0-90A0-3A0-30A0-9A0-90A0-3A0-30A
Readback
Accuracy (23±5ºC)
0.1%+0.1%F.S.
Power Measurement
Range0-3000W
Readback
Accuracy (23±5ºC)
0.5%+1%F.S.
Dynamic Mode
T1&T20.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms0.025-60ms1-60000ms
Resolution1μs1ms1μs1ms1μs1ms1μs1ms
Accuracy (23±5ºC)1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm1μs+100ppm1ms+100ppm
Others
InterfaceLAN/RS232/CAN
AC InputSingle phase, 220V AC±10%, frequency 47Hz~63Hz
TemperatureOperating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC

Operating Environment
Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa
Net WeightApprox. 28kg
Dimension3U, 132.5(H)*482.0(W)*612.0(D)mm