1. Product Description 
 FM-200 / Hfc -227ea
FM-200 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200 extinguishes a fire by a combination of chemical and physical mechanisms.
FM-200 provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM-200 agent is used in total flooding fire suppression systems.
FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.

Components of  FM200 Fire Suppression Systems
 
Advantage
 
* Very swift fire suppression. Reach extinguishing level ≤10s.

* Safe to people. People is safe when exposed at the FM200 gas discharge level.

* Low extinguishing concentration. Nearly no obscure to vision in person evacuation.

* Easy to clean. No residue left, and minimize damage to sensitive equipment.

* Environment friendly. Zero ozone depletion potential and zero global warming potential.

* Simple installation, with small storage space.
2. Working Principle

When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto" position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.


3. Cylinder Parameters






4. Different Working Models of FM200 Fire Suppression System






5. Other accessories







6. Work Shop

 
7. Product Application
 
• Bank vaults
• Libraries
• Book stores
• Electronic data processing
• Telephone exchanges
• Communication centers
 
• Transformer and switch room
• Control rooms
• Test laboratories
• Flammable liquid storage