on-Grid/off-Grid Intelligent Smart Energy Storage Bidirectional Converter/Inverter for Solar System 500kw

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 26000 ~ 27500

Description
Product Description

Product description
Deming Power energy storage products and system solutions solve power supply problems in areas with no and weak electricity, and achieve smart power supply and demand allocation. This system is designed for three-phase energy storage system, which can realize the functions of On grid power generation, off-grid inversion, and city power reverse charging. If the power grid is disconnected, the storage system can automatically and seamlessly switch to off-grid operation mode to ensure uninterrupted power supply.
1)Power peaking and valley filling. Meet various needs of customers;
2)Smooth output power, improve the proportion of grid acceptance;
3)  Ensure electricity safety;
Performance characteristics
(1)The 32-bit DSP (Digital Processor TI 2812) +ARM (Touch Screen Master Chip) platform is used for touch screen display and operation, which facilitates field operation and parameter setup. The core driver of DSP control and ARM realize peripheral functions such as display and communication to improve power reliability.
(2)Support RS485, WiFi, GPRS, Ethernet communication, satisfy customer remote monitoring and other functions; can display AC and DC side voltage, current, operation mode, operation status, fault information, and can upload related data to the Internet of Things platform through the communication interface, and can start and stop power supply, parameter settings and other operations through the computer or mobile phone;
(3)Adopt three-phase four-bridge arm structure, which can carry 100% unbalanced load;;
(4)Designed for smart grids and smart microgrids, accept grid dispatching, cut peaks and fill valleys;

(5)Meets the access of lead-acid accumulator, lithium power, super capacitor, vanadium battery and other different energy storage forms, and has a wide range of applications.

                                           off grid and on grid hybrid solar power system (Bidirectional system)
                                                            off grid and on grid wind turbine solar hybrid power system 
 

Detailed Photos





 
Product Parameters

Technical parameters of bidirectional inverter 300KW-1000KW

AC Side parameters
Operation mode Continuous
AC wiring modeThree phase four wire
Rated output power300KW500KW1000KW
Output overload capacity330KW550KW1100KW
DC voltage range
Maximum DC power330KW550KW1100KW
DC voltage range Vdc400-800Vdc400-800Vdc500-900Vdc
Recommended battery nominal voltage480V600V600V
Rated charging current625A833A1667A
Max input current688A917A1833A
Voltage accuracy±1%±1%±1%
Steady flow accuracy±1%±1%±1%
DC current ripple<1% IPP<1% IPP<1% IPP
On Grid charging and discharging mode              Constant power
Rated grid voltage(AC)220V / 380V / 440V220V / 380V / 440V220V / 380V / 440V
Grid voltage range(AC)±20%±20%±20%
Rated grid frequency50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz
Grid frequency range±10%±10%±10%
Rated power(THD)<3%(Standard grid)
Power factor  0.8leading-1-0.8lagging, adjustable
Independent inverter mode
Rated output voltage(AC)220V / 380V / 440V±1%
Output voltage distortion resistive load)
Rated output frequency50Hz / 60Hz ±1%
Voltage transition range<10% (Resistance load 0% <=>100%)
System Parameters
On/off grid switching time0ms
Max. conversion efficiency95%( Include isolation transformer)
Noise<60dB
Protection DegreeIP20
Working Temperature-25ºC~+45ºC
Cooling method Air cooling
Working humidity0~95%
Working altitude≤6000m, (Reduced usage for more than 2000m)
Emergency stopYes (via emergency stop button)
DisplayTouch screen
Communication modeRS485,WIFI,GPRS,Ethernet (Modbus protocol)
Dimensions 2010*1060*2000mm2800*1200*2000mm4000*1200*2000mm
Weight1.5t2.5t4t

*Above parameter only for reference. Could be custom made to user specifications.

Technical parameters of bidirectional inverter 50KW-200KW

AC Side parameters
Operation modeContinuous
AC wiring modeThree phase four wire
Rated output power50KW100KW200KW
Output overload capacity55KW110KW220KW
DC Side Parameters
Maximum DC power55KW110KW220KW
DC voltage range Vdc350-800Vdc350-800Vdc350-800Vdc
Recommended battery nominal voltage384V/420V/480V 420V/480V480V
Rated charging current130A/119A/104A238A/208A416A
Max input current143A/130A/115A262A/229A458A
Voltage accuracy±1%±1%±1%
Steady flow accuracy±1%±1%±1%
DC current ripple<1% IPP<1% IPP<1% IPP
On Grid charging and discharging mode              Constant power
Rated grid voltage(AC)220V / 380V / 440V220V / 380V / 440V220V / 380V / 440V
Grid voltage range(AC)±20%±20%±20%
Rated grid frequency50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz
Grid frequency range±10%±10%±10%
Rated power(THD)<3%(Standard grid)
Power factor 0.8leading-1-0.8lagging, adjustable
Independent inverter mode
Rated output voltage(AC)220V / 380V / 440V±1%
Output voltage distortion<3% ( resistive load)
Rated output frequency50Hz / 60Hz±1%
Voltage transition range<10%  (Resistance load 0% <=>100%)
System Parameters
On/off grid switching time0ms
Max. conversion efficiency95%( Include isolation transformer)
Noise<60dB
Protection DegreeIP20
Working Temperature-25ºC~+45ºC
Cooling method Air cooling
Working humidity0~95%
Working altitude≤6000m, (Reduced usage for more than 2000m)
Emergency stopYes (via emergency stop button)
Display Touch screen
Communication modeRS485,WIFI,GPRS,Ethernet (Modbus protocol)
Dimensions 750*600*1320mm1460*860*1820mm1460*860*1820mm
Weight340KG1.4t1.6t

*Above parameter only for reference. Could be custom made to user specifications.

Technical parameters of bidirectional inverter 10KW-30KW

AC Side parameters
Operation mode Continuous
AC wiring modeThree phase four wire
Rated output power10KW20KW30KW
Output overload capacity11KW22KW33KW
DC Side Parameters
Maximum DC power11KW22KW33KW
DC voltage range Vdc200-700Vdc200-700Vdc200-700Vdc
Recommended battery nominal voltage240V 384V 420V 480V240V 384V 420V 480V240V 384V 420V 480V
Rated charge current50A100A150A
Max input current  55A110A165A
Voltage accuracy±1%±1%±1%
Steady flow accuracy±1%±1%±1%
DC current ripple<1% IPP<1% IPP<1% IPP
On Grid charging and discharging mode              Constant power
Rated grid voltage(AC)220V / 380V / 440V220V / 380V / 440V220V / 380V / 440V
Grid voltage range±20%±20%±20%
Rated grid frequency50Hz / 60Hz50Hz / 60Hz50Hz / 60Hz
Grid frequency range±10%±10%±10%
Rated power(THD)<3% (Standard grid)
Power factor   0.8leading-1-0.8lagging, adjustable
Independent inverter mode
Rated output voltage(AC)220V / 380V / 440V±1%
Output voltage distortion<3% ( resistive load)
Rated output frequency50Hz / 60Hz ±1%
Voltage transition range<10% (Resistance load 0% <=>100%)
System Parameters
On/off grid switching time0ms
Max. conversion efficiency97%
Noise<60dB
Protection DegreeIP21
Working Temperature-25ºC~+45ºC
Cooling methodAir cooling
Working humidity0~95%
Working altitude≤6000m(Reduced usage for more than 2000m)
Emergency stopYes (via emergency stop button)
Display Touch screen
Communication modeRS485,WIFI,GPRS,Ethernet (Modbus protocol)
Dimensions 690*275*770mm   690*275*770mm 690*275*770mm 
Weight42KG58KG65KG


*Above parameter only for reference. Could be custom made to user specifications.