High Performance 5kw 12V Lab Test Repair Power Souce 5kw Digital Variable Switching DC Regulated Power Supply 12.5V 400A

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1033.78 ~ 1035.68

Description
PS-ATDY12.5400 12.5VDC 400A 5000W DC POWER SUPPLY 
AC INPUT: 1 phase 220VAC±15% 50/60HZ
DC OUTPUT: 0~12.5VDC, 0.1~400A 
Max power: 5000W 
Machine size: L483*W485*H135(MM)  
NW: 22KG, GW: 35KG
Protection:lower voltage, over-voltage, over current, short circuit, overheating 
Package: Pearl cotton and carton double protection
Model IPS-ATDY12.5400
AC Input Single phases 220VAC
Input Voltage Range220VAC±15%
Input frequency50Hz/60Hz
Output voltage 0~12.5VDC
Output current 0.1~400A
Output Power 5000W
Voltage Stabilization≤0.3%+10mV
Load Stabilization≤0.5%+30mV
Ripples and Noises≤0.5%+10mVrms
Voltage Display Accuracy4-digit Accuracy: ±1%+1 word (10%-100% rating)
Display Format0.000V-9.999V;  0.00V-99.99V;  0.0V-999.9V
Current Display Accuracy4-digit Accuracy: ±1%+1 word (10%-100% rating)
Remote Adjustment(Analog control: Voltage adjustable ):0-5VDC;(Current adjustable):0-5VDC
Remote Display(Analog control: Voltage adjustable ): 0-5VDC;(Current adjustable):0-5VDC
Output Over Voltage ProtectionBuilt-in O.V.P. protection, protection limited value is rated +5%
Output Over Load ProtectionOverload, current limit, constant current output
Over Temperature ProtectionBuilt-in O.T.P. protection, Protection value 85ºC±5%  heat sink temperature
Voltage Setting10-turn precision potentiometer
Current Setting10-turn precision potentiometer
Output PolarityOutput Positive(+) negative(- ) Can be grounded at will
Heat Dissipation WayForced fan cooling
Work ConditionsIndoor use design,Temperature:0ºC~40ºC; Humidity: 10%~85%RH
Storage ConditionsTemperature:-20ºC~70ºC;Humidity: 10%~90%RH
Machine /Package DimensionL483*W485H135(MM) /L69*W55*H26(CM)
Net weight/ Gross weight 22KG/35KG
 
MODELOUTPUT VOLTAGEOUTPUT CURRENTOUTPUT POWER
IPS-ATDY2520025VDC200A5000W
IPS-ATDY4012540VDC125A5000W
IPS-ATDY5010050VDC100A5000W
IPS-ATDY8062.580VDC62.5A5000W
IPS-ATDY10050100VDC50A5000W
IPS-ATDY12540125VDC40A5000W
IPS-ATDY20025200VDC25A5000W
IPS-ATDY25020250VDC20A5000W
IPS-ATDY40012.5400VDC12.5A5000W
IPS-ATDY50010500VDC10A5000W
IPS-ATDY6258625VDC8A5000W
IPS-ATDY8006.25800VDC6.25A5000W
IPS-ATDY100051000VDC5A5000W
IPS-ATDY125041250VDC4A5000W
IPS-ATDY15003.31500VDC3.3A5000W
IPS-ATDY20002.52000VDC2.5A5000W
IPS-ATDY250022500VDC2A5000W
IPS-ATDY30001.673000VDC1.67A5000W
IPS-ATDY500015000VDC1A5000W


Power supply adjustable is widely used in industrial control, electronic power, electroplating, communication, scientific research, instrument, medical, ship, railway and other high-tech fields.

The details are as follows:

1. Motor: electric motor, electric vehicle controller, dc motor test, etc

2. Electric tools: LED test and aging, energy-saving bulb testing and aging, lamp testing, tungsten gasification, etc

3. Automobile: automobile electronics, high power dc motor, automobile motor controller, car lighting, cigarette lighter, automobile audio and video, etc

5. Electronic devices: capacitors, resistors, relays, transistors, sensors, etc

6. Display: display screen, liquid screen, touch screen, on-board DVD, mobile phone display, etc

7. Electrochemical class: electrolysis, electroplating, anodic oxidation, nonferrous metal research, etc

 

Product Overviews

 

 
 

Operation-Adjustable dc power supply

1. Before connecting with loads, please preset the needed output voltage, or check the output voltage is suitable or not, or adjust the voltage potentiometer and current potentiometer to a minimum.
2. Please connect with loads when POWER OFF. Then turn Power ON. Turn the Voltage potentiometer, a current potentiometer to a minimum at first. After the power supply machine works steadily, then adjust the needed output voltage which can avoid the overshoot voltage to damage the load's equipment.
3. In-running status, you can adjust the voltage potentiometer, a current potentiometer to change the output voltage and output current as you need. 4. Internal fan is temperature-control, only when high temperature, the fan will work when low temperature the fan will stop.
5. Internal radiating wind hole: left-in and right-out, please make sure there is no barrier in the left and right wind hole.

Product Tag:
Related categories: