Foinoe X Ray Film E Speed X-ray Image Intensifier Radiografia De Animales High Frequency Portable Xray Machine

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 12000 ~ 23000

Description
Product Description

Multi-functional Portable DR Mobile X-ray Machine FN-MTM200

Specifications

Features:
1.   The portable Digital X-ray system is small and lightweight, with four universal wheels which can achieve real freedom of movement.
2.   Tube head has LCD touch screen, which can select body position and focus, and adjust kV, mAs,  mA and ms. This smart design is convenient for positioning and adjusting exposure parameters, which greatly improves the work efficiency ofradiographers.
3.   There is a large storage space for the flat panel detector. A password lock is designed to help the FPD management.
4.   Free stop tube arm for fast and accurate patient positioning.

Configurations
 
 No.BrandModelProduct NameQuantity 
1FoinoeTCQ -IVFlat Panel Detector1
 FoinoeTCQ -IIIFlat Panel DetectorOptional
2FoinoeDXRayDiagnostDXRay Diagnostic Workstation1
3FoinoeFSQ -5 -PD5EHigh Frequency Generator1
4FoinoeKL10SBX-Ray Tube1
5Foinoe Collimator1
6FoinoeMTM200Mobile Rack1
7DellIns 15 -3501 -R1605sLaptop1
     
SYSTEM CONFIGURATION
   WIFI FPD Detector
   Angell DXRayDiagnost
   5.6kW High frequency generator
   X-Ray tube
   Mobile rack
 
Static WIFI Flat Panel Detector
   Detector: Wireless detector
   Detector technology: Cesium iodide (CsI)scintillator coupled to TFT matrix with amorphous silicon
technology
   Image Size: 35×43cm (14×17 inch)
   Pixel Matrix: 2560×3072
   Pixel size: 140μm
   A/D Conversion: 16 bits
   DQE: 2μGy at 0 lp/mm 65%
   Spatial Resolution: 3.6 LP/mm
   Image Acquisition Time: 2s
   Image Processing Time: 3s
   Recommended cycle time:10s
   Communication: Ethernet
   Adapter Input: AC 100-240V,50-60Hz
   Adapter Output: DC 24V, 60W
   Dimensions: 38×46×1.5 cm
   Weight: 3.3 kg
   Max. load capacity 135 kg with patient lying on it; 100 kg with patient standing
   Battery: Lithium ion, build in, rechargeable, 3000mAh 2 pieces
   Charging time: 240 minutes for 100 % battery capacity
   Battery Standby Time: 12H
   Housing Material: Carbon, Alloy
   Water Tightness: IP54
   Operating Environment: 5-35 ºC,10-75% RH
DXRay Diagnostic Workstation
Dell laptop
   CPU: Intel i5 2.4GHz
   Memory: 16GB ,Hard Drive: 512G SSD
   Display: 15.6inch; Resolution: 1920*1080 pixels DXRayDiagnost software
Case management
   Case management function: including the management of patient information, exam information and images.
   Worklist enquiry service following standard DICOM3.0 may inquiry from HIS/PACS and download case information.
Image acquisition
   Acquisition system: positive and negative film image capture can be configured.
   Real time automatic window width level adjustment.
   Real time ROI (region of interests) clipping.
   Real time enhancement.
   Selecting image and rotation according to different body postures.
   Displaying patient information, examination information, device information and image information
Image processing
   Adjustment of window width, window level, Gamma, and LUT curve.
   Positive and negative film switchover, image zoom, translation, mirror image, rotation, magnified display, flip, invert.
   Image enhancement, noise reduction: Scheme and level of image enhancement and noise reduction can be adjusted according to different body postures.
   Image labeling function: including drawing straight line, rectangle, polygon, arrow and text.
   Real time reminding the free space of image disk ofthe system.
   RT prompt system can be used for store size ofthe disk space of image. Image output
   Sending SCU with DICOM: support sending image to any PACS and workstations following Standard DICOM3.0 through internet of 5G speed WIFI or Lan.
   Receiving SCP server with DICOM: support receiving image following Standard DICOM3.0 from any workstation.
   DICOM images can be saved as DICOM printer, folder, JPG, BMP, CD/DVD through the
driver.
Emergency mode: it can supply emergency exposure without registration
Check-up mode: it can import and register patient information by excel
Reject analysis: Image cancel / delete image / Statistic ofuse
Reject analysis: Image cancel / delete image / Statistic of u
5.6KW High Frequency Generator
  Nominal supply voltage: 100~264VAC
   Working Frequency: 80kHz~200kHz
   Maximum output power: 5.6KW
  Nominal Power: 5.6KW
   Tube Voltage Setting Range and Digital Display: 40 to 125kV, in 1kV increments
   Tube current: 5 to 100mA
   Current-Time Product Setting Range and Digital Display: 0.1-320mAs
   Exposure time range: 1ms- 10000ms
   Size: 383mm*240mm*214mm
   Weight: 14.5kg±0.5kg
X-Ray tube (KL10SB)
   Target angle: 15°
   Focal Spot Sizes: 0.6 / 1.8 mm
   Max. Anode Heat Content: 20kJ
   Max. heat content: 40 kJ
Collimator
   Max. Irradiation field (SID=100cm): rectangular irradiation field 430mm×430mm
   Power supply: 24VAC 6A
   Average illumination (at SID=100cm): 160 lx or more
Mobile Rack
   Max. distance from the tube focus to the ground (SID): 2000mm
   Tube rotation around support arm: 360°
   Tube rotation around tube axis: 350°
   Tube head LCD Screen console could select Focus, and adjust kV, mA, mAs, and ms; also indicates
exposure status and displays Error code.
   System size (L*W*H): 795mm*550mm*1450mm
   Total weight: 67kg (for whole machine)
Detailed Photos

 






Company Profile

 

Customer Photo

 


Send your message to us and click "Send" no
Product Tag:
Related categories:
Scroll to Top