Oximax Pediatric SpO2 Sensor dB9-9p 0.9 Meter White Cable SpO2 Finger Probe for Nellcor

Min.Order: 25
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 1.3 ~ 1.5

Description
Product Description
Disposable Blue Foam SpO2 Sensor Probe
Indications
The product is indicated for single use to collect and transmit signal of SpO2 and pulse rate of patient, with compatible monitors or oximeter. The product is only used by experienced medical professional or under their directions.
 
Operation principle, function and structure The patient sensor end of the product is attached on the patient's index finger (Thumb, middle finger or others, great toes), and the device connector is connected to compatible monitors or oximeter with SpO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as incident light source, tests light intensity through tissue to obtain SpO2 value as well as pulse rate. Operation principle, function and structure The patient sensor end of the product is attached on the patient's index finger (Thumb, middle finger or others, great toes), and the device connector is connected to compatible monitors or oximeter with SpO2 extension cord. The product adopts 660nm red light and 905nm Infrared light as incident light source, tests light intensity through tissue to obtain SpO2 value as well as pulse rate.
Specifications 1)Measurement Wavelengths and Output Power: Red: 660±5nm @ 2.0 mw maximum average Infrared: 905nm±5nm @2.0 mw maximum average Oxygen Saturation Declared; 2)Accuracy Range: ±3 % of 70%~79% SpO2; ±2% of 80%~89% SpO2; ±1% of 90%~100% SpO2; 3)Pulse Rate Range: 30~245 BPM; 4)Accuracy: ±3 bpm of 150 bpm ~245 bpm; ±2 bpm of 60 bpm~149 bpm; ±1 bpm of 30 bpm~59 bpm; 5)Response time: ≤30sSpecifications 1)Measurement Wavelengths and Output Power: Red: 660±5nm @ 2.0 mw maximum average Infrared: 905nm±5nm @2.0 mw maximum average Oxygen Saturation Declared; 2)Accuracy Range: ±3 % of 70%~79% SpO2; ±2% of 80%~89% SpO2; ±1% of 90%~100% SpO2; 3)Pulse Rate Range: 30~245 BPM; 4)Accuracy: ±3 bpm of 150 bpm ~245 bpm; ±2 bpm of 60 bpm~149 bpm; ±1 bpm of 30 bpm~59 bpm; 5)Response time: ≤30s
Specifications
Measurement Wavelengths and Output Power
Red: 660±5nm @ 2.0 mw maximum average
 Infrared: 905nm±5nm @2.0 mw maximum average Oxygen Saturation Declared;
Accuracy Range
±3 % of 70%~79% SpO2; ±2% of 80%~89% SpO2; ±1% of 90%~100% SpO2;
Pulse Rate Range
30~245 BPM;
Accuracy
 ±3 bpm of 150 bpm ~245 bpm; ±2 bpm of 60 bpm~149 bpm; ±1 bpm of 30 bpm~59 bpm;
Response time
 ≤30s