No. | Fault content | Fault description | Y/ N |
B0 | IPM over current protection | Out of IPM hardware loop setting (DC peak) | YES |
B1 | Compressor running out of step | Compressor out of step due to sudden change of load | YES |
B3 | Compressor out of phase | Any of phase out of for compressor U\V\W | YES |
B4 | Under voltage protection | DC bus voltage is less than 210V | YES |
B5 | Over voltage protection | DC bus voltage is higher than 435V | YES |
B6 | The radiator temperature is too high | The radiator temperature exceeds the set value | No |
B7 | Abnormal radiator sensor | Short circuit or break of radiator sensor | No |
B8 | Abnormal communication | The upper computer communication data cannot be received for 120 seconds continuously | YES |
B9 | Abnormal AC phase or CT | Input power under phase or abnormal AC current | YES |
B10 | High AC current protection | AC current exceeds the set protection value | YES |
B11 | AC voltage is too low | AC voltage is lower than the set value | No |
B12 | High voltage switch protection | High voltage switch interface is disconnected | Optional |
B13 | IPM over temperature protection | IPM over temperature protection | YES |
B14 | Compressor over current protection | Compressor current exceeds set value | Optional |
B15 | APFC protection | APFC protection temperature output exceeds set value | No |
B21 | EPPROM fault | EPPROM fault | YES |
B24 | Outer fan 1 fault | Rotate speed fault of fan 1 | YES |
B25 | Outer fan 2 fault | Rotate speed fault of fan 2 | YES |