Cabinet Description Product Overview The medical isolation transformer built in ZWM-1/3P series system cabinet is designed for medical occasions that require high-efficiency and low-noise isolation power supply, as well as for noise-sensitive medical instruments and precision measuring equipment. Features 1,The isolated power grid is completely independent of the power grid for power supply, which actively ensures the electrical safety; 2,The isolation power supply can generate new neutral line, which can avoid the operation defect of the equipment caused by the defective neutral line of the power grid; 3,The distortion of current waveform caused by nonlinear load in power grid can be isolated without being polluted by the power grid; 4,Real-time detection of the insulation resistance, power load and power grid output voltage after high-temperature tension isolation of isolation transformer in single-phase or three-phase isolated power grid; 5,Strict application of operation noise control technology to minimize noise; Product Application 1,Ventilator 2,Constant temperature incubator 3,Dialysis equipment 4,Anaesthetic equipment 5,Patient monitoring equipment 6,High frequency surgical equipment 7,Infusion pump 8,Injection pump 9,Heart-lung machine 10,Cardiograph 11,Pulsating press 12,Electronic heart rate regulator 13,Shadowless lamp 14,Operating room and hanging tower DesignDrawings Distribution Box System Diagram in Operating Rooms Distribution Box System Diagram in Delivery Room Distribution Box System Diagram in ICU Design considerations: 1,ZWM-1/3P series isolation power supply system, whether used in operating room, ICU, ICU ward or delivery room, must be designed with short-circuit protection and no overload tripping function. 2,The medical isolation transformer in ZWM-1/3P isolation power supply cabinet shall have the function of automatic heat dissipation and cooling. If the temperature does not drop, it shall have an over-temperature alarm to remind the electrician on duty for handling and maintenance in time to ensure electrical safety. 3,The insulation monitoring instrument must directly display the insulation value and the lower alarm limit, the voltage value after isolation, the upper and lower voltage limits, and the double temperature values. The first temperature is for starting heat dissipation system, and the second temperature is the upper alarm limit, and the insulation monitoring instrument is equipped with an audible and visual alarm, which can draw attention in case of failure. 4,More than 2 sets of medical IT isolation power supply system (simple) and external alarm test and display instrument (centralized display) 5,Difference between UPS and medical IT system UPS is the backup emergency power supply when the power of the normal power supply line is interrupted, and it can't prevent the leakage fault. When the load side of the common grounding system (YN-S) is with a grounding fault, no matter whether the system uses the UPS or the common power supply line, it can't limit the increase of the fault current. Only by adopting the IT system can the fault current be limited to the maximum extent, so as to achieve the purpose of protecting patients. Structure Diagram of Cabinet Circuit Configuration Diagram Standards and Certifications of ZWM-1/3PSeries Relevant standards and specifications for detailed design of medical IT isolation power supply system are as follows Architectural Technical Code for Hospital Clean Operating Department (GBS0333-2002) Code for Electrical Design of Civil Buildings (JGJ/T16-2008) Electrical Installations of Buildings-Part 7-710: Requirements for Special Installations or Locations-Medical Locations Code for Design of General Hospital (JGJ49-88) The product meets relevant standards Comply with the requirements in GB1689S.24/IEC 60364-7-710:2002 standard. Comply with the requirements in the national standard Requirements for Special Installations or Locations-Medical Locations (GB1689S.24). Medical Isolation Transformers Meet the Requirements of Building Electrical Devices-Part 7-710-Part 7-710 Requirements for Special Installations or Locations-Medical Locations GB1689S.24-2005/ IEC60364-7-710 : 2002 710.512.1.6 stipulates that medical isolation transformers meet the requirements of IEC61558-2-15. The insulation alarm system complies with IEC61SS7-8/1EC60364-7-710 standard. Declaration 1.Please read the instructions carefully before using this product, and the pictures, logos and symbols involved herein are owned by Zhejiang Zhuowoma Electric Technology Co., Ltd. Without the written authorization of our Company, all or any part of the contents shall not be publicly reproduced;
2.Before the isolation power supply system is powered on, please carefully read the tips and precautions in the product use and operating manual. We will not be responsible for any personal injury or economic loss caused by neglect of the operating manual;
3.Transformers and related insulation monitors are the Company's professional electrical equipment. Any operation related to transformers in isolated power cabinets shall be carried out by professional electrical technicians. We are not responsible for personal injury or economic loss caused by the incorrect operation of non-professional personnel.