35W 13.8V 27.6V AC to DC UPS Battery Backup Switching Power Supply

Min.Order: 1
Product origin: Wenzhou, Zhejiang, China
Infringement complaint: complaintComplaint
US$ 11.24 ~ 13.2

Description


ModelSC-35-12SC-35-24
 
 
 
output
DC voltageCH1:13.8VCH1:13.4VCH1:27.6VCH2:26.5V
Voltage tolerance±2%-----±1%-----
Rated current2.0A0.5A1.0A0.3A
Current range0~2.0A-----0~1.0A-----
Rated power34.3W35.6W
Ripple&noise120mvp-p-----120mvp-p-----
DCvoltage ADJ.rangeCH1:11.3~14.9VCH1:21.3~29.8V
 
 
 
input
Setup,rise,hold time800ms,50ms,80ms/230VAC,  1600ms,50ms,16ms/115VAC
Voltage range90~264VAC,127~370VDC
frequency47~63HZ
AC current0.9A/115VAC,0.45A/230VAC
efficiency81%83%
Inrush currentCold start current 25A/115VAC,45A/230VAC
Leakage current< 1mA/240VAC
 
protection
Over loadRated output power110%~150%  start over load protection
protection mode: AC charging mode:hiccup mode auto-recovery after fault condition is removed
Battery protection
At low voltage
9.5~11V20~22V
protection mode:cutoff output
FunctionUPS introductionlong-term online floating charge to battery,high charging efficiency,battery can saturate to more than 90% ,cauto-stop charging when it's full,prevent over charging. Effectively extend battery life,AC/battery auto switch ,no switch time,no need human guard,
cold-start ,when there is no AC input ,can use battery start UPS,Meet the user's emergency needs
environmentWorking temp,humidity-10ºC~+60ºC,20%~90%RH
Storagetemp,humidity-20ºC~+85ºC,10%~95%RH non-condensing
Withstand vibration10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes
safetyWithstand voltageI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistanceI/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC
FitstandardSafety standardCompliance to UL60950-1,EN-60950-2006
EMC standardCompliance to EN55022,CLASSB
othersDimension111*78*36mm (L*W*H)
Weight/packing0.3kg/50pcs/16kg/0.027m³/0.96CUFT
note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25ºCof ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.

Product Tag:
Related categories: