Model | IPS-SPT12125 | IPS-SPT15100 | IPS-SPT2075 | IPS-SPT2560 | IPS-SPT12512 | IPS-SPT2506 | IPS-SPT3005 |
Item | Technical indicators |
Output | DC voltage | 12VDC | 15VDC | 20VDC | 25VDC | 125VDC | 250VDC | 300VDC |
Rated current | 0~125A | 0~100A | 0~75A | 0~60A | 0-12A | 0~6A | 0~5A |
Rated power | 1500W |
Ripple and noise | <150mV | <150mV | <240mV | <240mV | <240mV | <240mV | <240mV |
Voltage accuracy | ±1% |
Output voltage regulation range | 0~12VDC | 0~15VDC | 0~20VDC | 0~25VDC | 0~125VDC | 0~6VDC | 0~5VDC |
Load adjustment rate | 0.3% |
Linear adjustment rate | 0.5% |
Input | Voltage range | 180-264VAC 340-440VAC;254VDC~370VDC |
Efficiency (typical) | >85% |
Working current | 220VAC;21A |
Impulse current | 60A 230VAC |
Start, rise, hold time | 2000ms,50ms,20ms;230VAC |
Protect | Over temperature protection | 105% ~ 135% type; Constant current output + V0 drop Undervoltage point cut-off output reset; Power on again |
Over temperature | RTH3;The fan operates normally, ≥ N90°C, and the output is closed |
Environment | Operating temperature, humidity | -10°C~+50°C;20%-90RH |
Storage temperature, humidity | -20°C~+85°C;10%~95RH |
Safety regulations | Withstand voltage | Input-output: 1.5kVac input housing: 1.5kVac output housing: 05kvac for 1 minute |
Leakage current | Input-output 1.5KVAC Time< 6mA |
Leakage current | Input-output 220VAC Time<1.5mA |
Isolation resistance | Input-output, input-housing, output-housing,500VDC/100MΩ |
Other | Size | 291*132*68(MM) |
NW/GW | 3KG/4.5KG |