2500V/5000V/10000V LCD Display Water Internal Cooling Generator Insulation Resistance Tester

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 600 ~ 1300

Description
2500V/5000V/10000V  LCD Display Water Internal Cooling Generator Insulation Resistance tester

1.Overview

    The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, HM2306 10KV insulation resistance tester has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used  to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.


2.Technical specifications
Safety specifications
-IEC 61010-1 CAT.IV 600V pollution level 2
-IEC 61326, EMC specification: electrical equipment for testing, control and inspection
-IEC60529 IP64 (outer box closed state)

The instrument is in line with international safty standards IEC610101:2001.
This instrument performs standard Q/WKD10.
-Insulation resistance: 50 MW  (between line and shell)
-Withstand voltage: AC, 10kV, 50Hz, 1min (measuring line and shell)
-Temperature and humidity: -30ºC ~ +60ºC  85%RH
-Storage temperature & humidity: -15ºC ~ +55ºC  90%RH
-Battery powered: two group battery charging together, 16V lithium ion rechargeable battery 2600mAH ,7.4v 2200mAH or charging side measurement.
Power charge:220V±10%,50/60HZ
-Size : 38.5. x 29.8. x 19.6.
-Weight: 4.5kg
-5.7inch screen display, resolution: 320*240
-Display mode: digital and analog pointer double display


3.Measurement accuracy

Rated voltage(kV)0.25,0.5,1,2.5,5
Measurement voltage(kV)Rated voltage×(1±10%), The load resistance is not less than 1% of the test range
Minimum error is 5%
RDG range
(0.001~100)GW/5kV
(0.001~200)GW/2.5kV
(0.001~50)GW/1kV
(0.001~20)GW/0.5kV
(0.001~5)GW/0.25kV
(0.001~100)GW/10kV
(0.001~200)GW/5kV
(0.001~200)GW/2.5kV
(0.001~100)GW/1kV
(0.001~20)GW/0.5kV
Maximum error is 10 %
RDG range
(100~200)GW/5kV
(5~10)GW/0.25kV
(100~200)GW/10kV
 (100~200)GW/5kV
Maximum error is 20 %
RDG range
(200~1000)GW/5kV
(200~500)GW/2.5kV
(100~200)GW/1kV
(200~1000)GW/10kV
(200~1000)GW/5kV
(200~500)GW/2.5kV
(100~200)GW/1kV
Output short circuit current≥8mA≥8mA
Absorption ratio,Measurement range of polarization indexMeasurement range: 0.01 ~99.99
Maximum error: ±(1%RDG+1d)
Measurement range: 0.01 ~99.99
Maximum error: ±(1%RDG+1d)
Output voltage display error±(3%RDG + 1d)±(3%RDG + 1d)


4. Details photos



6.Features.

1. True automatic discharge function, no need to manually discharge.
2. High output power of the instrument, real-time voltage measurement (actual charged voltage of the sample), leakage current measurement, automatic discharge (discharge voltage measurement)
3. Intelligent voice prompt function
After starting up, the voice prompts "Welcome to use the anti-interference insulation resistance tester, please select the appropriate voltage for measurement". After starting, the voice prompts "Do not approach the high voltage danger". After the automatic measurement is completed, the voice prompts "Measurement is over, it is discharging automatically, then the discharge is completed, and the discharge voltage is 0v.
1).Designed in strict accordance with safety standards, output voltage: 500v 1000v, 2500v, 5000v, 10000v.
2).This instrument automatically calibrates the function and automatically calibrates the accuracy before testing.
3).This instrument has the actual test product charging voltage measurement function, leakage current measurement function, automatic discharge function. It can be visually seen through the actual test product charging voltage measurement function whether the drop voltage of the test instrument after the load meets the national requirements. Moreover, the actual test sample charging voltage measurement function and leakage current measurement function can visually see the quality of the sample insulation.
4).It can automatically measure and memorize R15S, R60S and R10min values, and automatically display the polarization index (PI), the induced absorption ratio (DAR) test value and test time.
5).Automatic discharge: The advanced high-voltage discharge technology is used to quickly discharge the capacitive sample. The discharge voltage is measured in real time during discharge (test sample voltage is 0v). For example, the test sample voltage is 10000v, then the discharge is stopped by 10000v when the test is stopped. Go to 0v (real-time visual display) to monitor the discharge voltage in real time, and prompt "safe disconnection", the operator can disconnect the line (for the extra large test sample, after the automatic discharge, please perform manual discharge to remove the line!) .
6).Internal rechargeable lithium battery power supply or AC power supply, the real AC and DC does not affect the test accuracy.
7).Battery power digital display and undervoltage alarm protection.
8).Intelligent battery charging management can effectively prevent battery overcharging.
9).Short circuit protection, the instrument will not be burnt out in the short circuit condition (use the voltage level within 2500V as much as possible in the nuclear phase).


6. Related Products.


6. Company profile


Wuhan Goldhome Hipot Electrical Co.,ltd is an ISO certified factory specially in  manufacture electric test equipment with more than 20 years experience , located in Wuhan city , China .
Main products included PD free test set, AC/DC hipot tester, transformer tester, CT/PT analyzer , Circuit breaker tester, relay test set, transformer oil tester ,etc .
Warmly welcome to visit Goldhome Hipot factory !



Product Tag:
Related categories:
Scroll to Top