300V Copper Wire 14/2 Nmd90 Wire

Min.Order: 10,000
Product origin: Tangshan, Hebei, China
Infringement complaint: complaintComplaint
US$ 0.3

Description
Our C(UL) certificate number for this cable is E487898.
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.

The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation.

The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.
 

CODES / STANDARDS

NMD90 cables meet or exceed the
following requirements:

CONSTRUCTION

ASTM
CSA C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code1

NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.

Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below

 
JACKET COLOUR CODE - Typical Application Guide

•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
CABLE PRINTING
12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON 300 VOLTS FT1

NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external lubricants, resulting in reduced labour and materials costs.


PVC / NYLON INSULATION
PVC JACKET
GROUND CONDUCTOR COPPER CONDUCTOR PVC / NYLON INSULATION
PVC JACKET
SPECIFICATION
ConductorInsulationGroundApprox. Jacket thicknessApprox. Cable Dia.Approx. Cable weightAllowable Ampacities 30°C
Size
(AWG)
CoresStrandsInchesmmSize
(AWG)
CoreInchesmmInchesmmIb/
1000ft
Kg/
km
 
14210.0340.861410.0300.760.388*0.1929.86*4.886810125*
14210.0340.861410.0300.760.388 x 0.1929.86 x 4.886810125*
12210.0340.861410.0300.760.422 x 0.20910.71 x 5.308612930*
10210.0340.861210.0300.760.481 x 0.23012.21 x 5.8412218240*
8270.0401.021010.0451.140.636 x 0.31216.15 x 7.9220831055
6270.0511.30870.0451.140.792 x 0.37020.12 x 9.4031546875
14310.0340.861410.0300.760.3458.778612825*
12310.0340.861410.0300.760.3819.6911416930*
10310.0340.861210.0300.760.42710.8516324240*
8370.0401.021010.0451.140.57014.4727540855
6370.0511.30870.0451.140.69517.6542162775
3370.0511.30670.0802.030.92523.487991189115
             
 
 
 


 