Input & OutputAnalog input1 channel,voltage / current signal can be switched,voltage 0~10V,current 0~20mA
Digital input5 channels,Optocoupler isolation
Analog output1 channel, voltage 0~10V,current 0~20mA,Output type switchable
Digital output1 channel, Optocoupler isolation / open collector output / rated current 20mA (Y terminal)
Digital pulse output1 channel,Optocoupler isolation / open collector pulse (frequency or PWM) output (Y terminal)
Relay output1 channel,Normally open and normally closed contact, 250VAC-3A
Communication modeStandard MODBUS-485 communication protocol
Control characteristicscontrol modeSpace voltage vector control mode
Frequency setting modeKeyboard setting, analog setting, pulse setting, PID, communication setting and others
Frequency control range0.01~400Hz
Speed regulation ratio1:100
Steady speed accuracy±0.5%(SVC)
Multistage speed controlBuilt in simple PLC can control the maximum 16 speed frequency logic
Carrier adjustable1.0~16kHz ,adjusted according to the module temperature
Important functionsShutdown mode, bus overvoltage protection
Protection functionOverload capacity60s-rated current x 150%; 10s-rated current x 180%;3s-rated current x 200%
Open phase protectionIn case of phase loss at the input or output end, the motor stops freely
Overheat protectionThreshold can be set freely according to the ambient temperature, accuracy is ± 3 ºC
Stall protectionPrevent stall during acceleration or deceleration or operation (working current can be set)
Grounding protectionby current sensor
Instant stopThe load feedback energy compensates for the voltage reduction and maintains the continuous operation of the frequency converter in a short time
Specification structureRated inputvoltage:1PH220V±15%; 3PH380V±15%
Frequency
:50Hz/60Hz±5%
Cooling and protectionIP20;forced cooling
Use environment-10ºC~+50ºC;Derating above 40 ºC; Altitude: not higher than 1000m; Indoor, no corrosive gas
Preservation environment-20ºC~+65ºC;Humidity: 20-90% RH (no condensation); shock <6m/s2(0.6g)