Skz2050b-5-Carbon Disulfide CS2 Sound Light Alarm Gas Testing Machine Gas Testing

Min.Order: 1
Product origin: Jinan, Shandong, China
Infringement complaint: complaintComplaint
US$ 1524

Description

Sound light alarm SKZ2050B-5-Carbon disulfide CS2 gas alarming device gas testing machine gas tester gas testing



Sound light alarm SKZ2050B-5-Carbon disulfide CS2 gas alarming device gas testing machine gas tester gas testing to measure Carbon disulfide CS2 gas with pump built-in.
 

Note: our product has different measuring ranges. If you are not sure which one you use or have any questions, please send me an inquiry directly, and I will solve your doubts.

If you think it is suitable, you can also choose to place the order directly. After we receive your order, we will ship it for you within 7-10 days or faster. 
Introduction:
It is used for on-site gas concentration detection and alarm for excessive gas concentration. It can detect the concentration of various toxic and harmful flammable gases, and display the real-time concentration value and standard signal output on the spot.

Use imported brand gas sensors (Honeywell, Japan Nemoto, British CITY, British Alpha, British Dynament, Swiss Membrapor, etc.) gas sensors,

The main detection principles are: electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion. It has the advantages of stable signal, high sensitivity and precision, and the flameproof wiring method is suitable for various dangerous places.

Features:
Explosion-proof, anti-lightning, anti-static, reverse connection, anti-EMI, EMC electromagnetic interference, anti-pulse surge current impact.
 Comply with the latest national standards and obtain the CPA measuring instrument type approval certificate, explosion-proof certification and other qualifications.
Three-wire system or four-wire system 4-20mA standard signal output, voltage output, 2 sets of relay switch values.
 It also has a standard bus system RS485 output (RTU format), optional integrated sound and light alarm.
 Optional with extra charge wired transmission, LAN, Internet, wireless transmission (2 kilometers, 5 kilometers, unlimited distance).
 The wireless transmission method can be 433, GPRS, WIFI, and other methods.
 The standard infrared remote control can be operated in dangerous situations without opening the cover, and the remote control distance is 15 meters, which is simple and practical
 Each unit can be switched to each other, automatically track the zero point to prevent drift, multi-level calibration.
 It can communicate with the computer, monitor the concentration of the field probe in real time through the upper computer on the computer, and store, analyze and print the data on the computer.



Technical Parameters:

Detection gasCarbon disulfide CS2
Scope of detection0-50,100ppm
Resolution0.01ppm
Detection principleElectrochemical principles 
Sensor life2years
Detection accuracy≤±3%F.S  
Linearity≤±2%
Repeatability≤±2%
uncertainty≤±2%
Recovery Time≤30S
Response timeT90≤20S
Signal outputBus system RS485 (RTU), three (four) wire system 4~20mA,
Optional: 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission, network transmission, SMS alarm.
Working environmentTemperature: -40ºC~+70ºC, humidity: ≤10~95%RH (normal)
Display method1.7-inch high-definition color screen display on site
Operating Voltage12~36VDC DC, the standard power supply of a single device is 24V, 1A or more than 1A DC regulated switching power supply
Power reference24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors
Way of workingFixed installation, online detection, diffusion measurement; pipeline, flow, and pump-suction measurement are available.
Installation methodPipeline type and wall-mounted type. The working pressure of the pipeline type is ±30% of the atmospheric pressure, and the pressure needs to be reduced if it exceeds the range.
Alarm methodThe default is 1 channel, optional 2 passive contact (dry node) output, three-level alarm, and the alarm point can be set. On-site sound and light alarm (optional).
Connecting cables4~20mA three-core shielded cable, RS485 select four-core, single wire diameter ≥1.5mm when the distance exceeds 1000 m; the shielding layer is connected to the earth.
Protection levelIP65
Explosion-proof Flameproof, ExdIICT6Gb  
Dimensions238×152×90mm(L×H×W) without alarm,
238×210×90mm(L×H×W) with alarm  
weightwithout alarm1.38Kg   with alarm1.6kg  
Packing listManual, warranty card, packing box
Optional accessoriesIntegrated alarm lamp, power adapter, split alarm lamp, drying cylinder, flow-through connector, threaded welding seat, AC AC pump, DC brushless pump, vacuum pump, rain cover, water vapor filter, U-shaped buckle, 304/ 316/316L stainless steel gas chamber, 304/316/316L stainless steel housing