Ys-8000d Medical Equipment Biphasic Automatic Portable Ambulance Cardiac Defibrillator and Monitor

Min.Order: 1
Product origin: Guangzhou, Guangdong, China
Infringement complaint: complaintComplaint
US$ -1

Description

YS-8000D  Biphasic Automatic Portable Ambulance cardiac Defibrillator and Monitor

YS-8000D Biphasic Defibrillator
 
Physical characteristics:
Main unit: Portable
Dimensions:L320xW205xH410
Weight:9.5kg
 
Technical specifications  
DEFIBRILLATOR.
 (1)Defibrillator type                    Manual, Synchronized, Asynchronized,  
 (2)Out put waveform                  Biphasic technology                                                                          
 (3)Energy accuracy                 ∠+1%
 (4)Energy selection       0,3,5,7,10,20,30,50,100,200,300,360 joule(nominal ata resistance of 50)
 (5)Charging time                     Maximum 8 seconds to 360 Joules
 (6)Standard Adult/Pediatric Paddles   Reusable external adult paddles(pediatric paddles integrated)          
Power requirements.
(a)AC Power supply                    110V, 60 Hz /220V,50 Hz  
(b)Vehicle Voltage            DC 12V
 
Internal Battery Backup
(1)Battery type                Rechargeable lead-acid battery
(2)Charging time                Time-Minimum of 4 hours for full charging  
(3)Battery charging       During AC Power Supply operation of the device.
(4)Charging /Low Battery Indication     Red LED              
(5)Battery Capacity       100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 joules.
Display
-LED Dimensions   7'diagonal {155mm*88mm} which is easily read from a distance.
-Type                    High resolution true-color graphic LED
-Resolution           480X234
- Provide cardioversion facilities with waveform annotated on the screen
- Display 4 seconds of ECG at 25mm/sec, ECG selectable from leads I, II, III when used with a 3-lead cable, and I, II, III aVL, aVR, aVF and V when used with a 5-lead cable.
- Display prompts, waveform settings, battery status, event summary and fault codes. Energy selected is displayed by push button under the screen.
ECG
ECG lead:  AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

Respiration
Measurement method: Thoracic impedance
Standard parameter & configuration
 ECG/ RESP/DEFIBRILLATOR
 
-Provide audible and visual alarms for heart rate violations, VF and VT.
-Provide a strip printer which annotates waveforms, events, time code
-Have a 5-lead patient cable as an option to a 3-lead cable.
-Supplied with external re-usable paddles and packs of paper rolls for the printer.



 