No. | Item Name | CBA-III High Voltage Circuit Breaker Tester |
1 | 12 channels for time measurement | 3-channel support both the time contact and resistance contact time 6-channel isolated contacts for cascaded unit measurement of pole |
2 | Time measurement | Range: 4000ms; Error :< 0.1ms; Resolution: 0.01ms |
3 | Travel measurement according to sensor | Linear resistance sensor: Measurement range: 0~250mm; resolution: 0.01mm; error: <0.5mm Measurement range: 0~25mm; resolution: 0.01mm; error: <0.05mm Angle resistance sensor: Measurement range: 0~360°; resolution: 0.01°; error: <0.5° |
4 | Pre-insertion resistance measurement | Range: 50~5000ohm; error :<1%RDG+2D |
5 | Dynamic resistance measurement | Test current: 25~100A, Measurement error :< 1%RDG+2D |
6 | Contact resistance measurement | Range:0--10mohm, Error <0.5%RDG+0.05%FS Range: 0-2mohm, Error: <0.5%RDG+2D |
7 | Speed measurement | 250mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D 25mm linear resistance scale: 0~20m/s; error: <0.5%RDG+2D Angle sensor: 0~20m/s; error: <0.5%RDG+2D Acceleration sensor: 0~20m/s; error: <5%RDG+2D |
8 | Coil current measurement | Range: 0~20A; resolution: 0.001A; error: <0.01A |
9 | Vibration measurement | Range: 0~5000G; error: <3% |
10 | Internal DC power source | voltage: 12~265V; current:0~20A |
11 | Data transaction | Built-in 8G storage memory and 2 USB interface for data export |
12 | Power supply | AC220V±10%; 50Hz±10% |
13 | Working environment | -10~50°C; Humidity: <80% |
Software introduction:
Accessories and Packing:
CBA-III used at site: