Online Double Conversion UPS Power Supply with No Break 1kVA 2kVA 3kVA 5kVA with DSP Technology and LCD Display

Min.Order: 10
Product origin: Shenzhen, Guangdong, China
Infringement complaint: complaintComplaint
US$ 100 ~ 250

Description
S1-5KVA LV (110V / 120VONLINE UPS Datasheet

Feature:
Zero Transfer time
True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues.

DSP Digital Control Based
Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply

Ultra Wide Input Mains range
Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  60V~145V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life

Best Loading Capability
Up to 0.9 Output Power Factor , 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application

Genset Compatible
Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.

High Input power factor
Thanks to digital controlled PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer

Reliable design
Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion.

Open to customization
Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system

Specification:
 
ModelS1K-LVS1KL-LVS2K-LVS2KL-LVS3K-LVS3KL-LVS5K-LVS5KL-LV
CapacityVA/W1kVA/900W2kVA/1.8kW3kVA/2.7kW5kVA/4.5kW
TopologyDouble Conversion Online UPS
PhaseSingle Phase Input Single Phase Output
AC
Mains Input
Wiring1 phase 3wires ( L / N+PE)
Rated Voltage110/115/120/127Vac
Voltage RangeLine-Neutral: 55~145VAC
Frequency Range40Hz-70Hz
Input Power Factor≥0.99
AC OutputWiring1 phase  L/N+PE
Output Voltage  110/115/120/127VAC
Voltage Regulation±2%
Output Frequency50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
WaveformPure Sine Wave
Distortion
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Over load capability1Min@105%~125%Rated Load
30Sec.@125%~150%Rated Load
0.5Sec.@>150%Rated Load
10min@105%~125%
60s@125%~150%
0.5S@>150%
EfficiencyAC/AC Mode88%89%90%92%
DC/AC Mode85%86%87%90%
Battery
&
Charger
Rated Battery Voltage 24VDC
Internal
36VDC
External
48VDC
Internal
72VDC
External
72VDC
Internal
96VDC
External
144VDC
Internal
192VDC
External
Battery Capacity12V/7AH
x2pcs
External Battery Depends 12V/7AH
X4pcs
External Battery Depends 12V/7AH
X6pcs
External Battery Depends12V/7AH
X12pcs
External Battery Depends
Backup Time>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load>6mins @ Half Load
Charging Current standard Model with Internal Battery:1A
Long Backup Time Model :4A
PhysicalChassis StyleTower
Tower Dimension
W x H x D (mm)
1KS: 145 x 220 x 250
1K: 145 x 220 x 318
2K, 2KS::145 x 220 x 390   
3K/3KS: 190 x 318 x 368
5K, 5KS:190 x 360x 528
Weight (kg)8.94.2145.921.68.33716
HMILCD DISPLAYInput Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards
Communication
1.  RS232 PORT
Optional Extension Card
  1. NMC Card:  Support remote monitor the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
  2. CMC MODBUS Card, 
  3. USB Card
  4. Relay Card  (Needs assembly according to order request before shipping)
Operating Environment
Endurance
Temperature range-10~50oC
Relative Humidity 0-98%(Non-condensing)

Acoustics Noise

<55dB @ 1 meters

DETAIL IMAGES



Product Tag:
Related categories:
Scroll to Top