HDM1100 Alarm Digital Display Intelligent Temperature Controller

Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 30 ~ 40

Description
Product Overview:

HDM1100 Simple single loop digital display control instrument, fool operation, a 0.3 magnitude measurement precision, seven new appearance size, double four LED display, can support the thermocouple, heat resistance, voltage (root operation), current (root operation) and input in the transmitter, suitable temperature, pressure, flow, liquid level, humidity, such as industrial process monitoring.It supports 2-way alarm function, 1-way transformer output or RS485 communication interface using standard MODBUS protocol, 1-way DC24V feed output, photoelectric isolation of input end, output end and power end, 100-240V AC/DC or 12-36V DC switching power supply, standard snap-in installation, working environment temperature is 0-50ºC, and relative humidity is 5-85%RH without condensation.

Features:

1. Display panel appearance structure drawing



(1) PV display window (measured value)
(2) SV display window
Display input type and other parameters in measurement state
Displays the set value in the parameter setting state
(3) First alarm (AL1) and second alarm (AL2) indicator light, RUN light and output light (OUT)
(4) Confirm key
(5) Shift key
(6) Reduced bond
(7) Increase the key
The meter core can be pulled out of the case, the method is to remove the lock on both sides of the front panel of the meter to the outside, and then grab the front panel of the meter to pull out, the table core and the case can be separated.In the back, the watch core inserted into the case must be pushed tight, and lock lock lock, in order to ensure protection standards.

Outline dimensions and hole dimensions of the instrument:
 
Outline DimensionHole DimensionOutline DimensionHole Dimension
160*80mm
(Horizontal type)
152*76mm48*96mm
(Vertical Type)
45*92mm
80*160mm
(Vertical Type)
76*152mm72*72mm
(Quadrate Type)
68*68mm
96*96mm
(Quadrate Type)
92*92mm48*48mm
(Quadrate Type)
45*45mm
96*48mm
(Horizontal type)
92*45mm  


Structure Drawing:





The dimensions are A, B, C, D and E wiring diagrams
Note: The direction of the terminals on the back cover of horizontal and vertical instruments is different. As shown in figure 1.

F Wiring Diagram


H Wiring Diagram

Note: If different functions are marked on the same set of terminals in the wiring diagram above, only one of the functions can be selected.For example, RS485 communication function and transformer output function are on the same set of OUT terminals, only one of them can be selected.


Ordering Guide:
 
1. Specification2. Graduation Input
CodeWidth*Height*DepthCodeGraduation (Measuring Range)
A160*80*110mm (Horizontal type)0Thermocouple B(400~1800ºC)
B80*160*110mm (Vertical Type)1Thermocouple S(0~1600ºC)
C96*96*110mm (Quadrate Type)2Thermocouple K(0~1300ºC)
D96*48*110mm (Horizontal type)3Thermocouple E(0~1000ºC)
E48*96*110mm (Vertical Type)4Thermocouple T(-200.0~400.0ºC)
F72*72*110mm (Quadrate Type)5Thermocouple J(0~1200ºC)
H48*48*110mm (Quadrate Type)6Thermocouple R(0~1600ºC)
3. OUTPUT7Thermocouple N(0~1300ºC)
CodeOutput Type ( load resistance RL)8F2(700~2000ºC)
XNo output9Thermocouple Wre3-25(0~2300ºC)
04-20mA(RL≤500Ω)10Thermocouple Wre5-26(0~2300ºC)
11-5V(RL≥250KΩ)11Thermal Resistance CU50(-50.0~150.0ºC)
20-10mA(RL≤1KΩ)12Thermal Resistance CU53(-50.0~150.0ºC)
30-5V(RL≥250KΩ)13Thermal Resistance CU100(-50.0~150.0ºC)
40-20mA(RL≤500Ω)14Thermal Resistance PT100(-200.0~650.0ºC)
50-10V(RL≥4KΩ)15Thermal Resistance BA1(-200.0.0~600.0ºC)
D1RS485 communication interface (Modbus RTU)16Thermal Resistance BA2(-200.0~600.0ºC)
4. Alarm (Relay contact output)(See Note)17Linear Resistance 0~1KΩ(-1999~9999)
CodeAlarm Ways18Remote Resistance 0-350Ω (-1999~9999)
XNo Output19Remote Resistance 30-350Ω (-1999~9999)
11 way Alarm200~20mV (-1999~9999)
22 way Alarm210~40mV (-1999~9999)
5. Power Output220~100mV (-1999~9999)
CodePower Output (Output Voltage)23Internal retention
XNo output24Internal retention
PPower Output(Load Current≤30mA)250~20mA (-1999~9999)
Such as "P(24)"says Power Output24V.260~10mA (-1999~9999)
6.Power Supply274~20mA (-1999~9999)
CodeVoltage Range280~5V (-1999~9999)
AAC/DC 100-240V (AC/50-60Hz)291~5V (-1999~9999)
DDC 12-36V30Internal retention
7.  Remark310~10V (-1999~9999)
No remarks can be omitted320~10mA Square Root (-1999~9999)
334~20mA Square Root (-1999~9999)
340~5V Square Root (-1999~9999)
351~5V Square Root (-1999~9999)
55All Switch


Related Products:











Certification:






FAQ:

1.   Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.   Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.   Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.
 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.      Q: What's the transport?                                                            
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           A: We could accept T/T, Paypal, WU.
Product Tag:
Related categories:
Scroll to Top