<1>. Working Principle: Open loop direct measurement.
<2>. Product Usage: Used for measuring DC, AC, pulse current and other arbitrary waveform current.
<3>. Product Advantages: Better cost performance, low power consumption, small volume, light weight, easy installation,
perforation input and no insertion loss.
<4>. Product Application: Frequency conversion speed control system, electric welding machine, electrochemistry, power supply monitoring, electric locomotive, low level starting protection.
<5>. The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability.
*Full channel configuration,Parameter customizable
Similar products
Installation | Standard rail+Plane screw fixation |
Original side rated current | 1mA;5mA;100mA;0.5A;1A;2A;5A;10A;customization |
Original side measurement range | 1mA-10A |
Rated output | 5V;10V;DC4-20mA;0-20mA |
Auxiliary power supply | DC12V,DC24V |
Load capacity | 5mA |
Linearity | 0.5% |
Accuracy | 1% |
Overload capacity | Double nominal input, sustainable |
Temperature drift | ≤500PPM/ºC |
Band width | DC~20KHz |
Consumption of current | ≤25mA |
Working temperature | -10ºC~+70ºC |
Storage temperature | -25ºC~+85ºC |
Response time | <200mS |
Isolation pressure resistance | 2.5kV/50Hz,1Min |
Offset Voltage | ≤20Mv |