Acrel LCD DIN Rail 0-1000V Input DC Digital Energy Meter Work with Shunt /Hall Sensor for Charging Pile and Solar PV Support Two DC Metering Djsf1352-Rn

Min.Order: 1
Product origin: Wuxi, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 103.6

Description

Product Description

DJSF1352-RN Din Rail DC Power Meter

General
DJSF1352-RN din rail DC power meter with dual channel DC input is suitable for telecommnications base stations,dc chargingpiles,solar pv and other applications.It can measure voltage,current,power,forward and reverse energy and so on in DC system.Itcan also measure total power and energy within a period of time.
The meter have infrared communication interface and RS-485 communication interface, and supports Modbus-RTU protocol andDLT645-97 (07) protocol at the same time. The meter can have relay alarm output and digital input function; You can set the ratio,alarm, and communication through the meter panel keys according to different requirements. The meter can have event recording ofswitch (Modbus protocol), programming and event setting records (645 protocol), instantaneous and timing freeze function of data(645 protocol), maximum and minimum value recording function of voltage and current power.



Features

Dual Independent DC Circuits Monitoring

  For Twin EV Charger&Battery

  Voltage Input:DC 0~1000V

  Current Input (by Shunt): 0~75mV

  Current Input (by Hall Sensor): 0~5V, 0~10V, 0~20mA, 4~20mA

Built-in Bipolar Power Source
 
  Power Supply for Hall Effect CT

  Range: DC -12V ~ DC +12V

Optional Dual RS485 Communication

  Protocol: MODBUS-RTU

  1 RS485 (standard)

DO/DI Function

  2 DO (2A/30V DC; 2A/250V AC)
 
  2 DI (dry contact)


Technical Parameters
 

Technical parameters

 

Indicators

Input

Nominal value

Voltage input range

Current input

DC 0-1000V

See the physical wiring diagram

Shunt:0-75mV;

Hall sensor:0-20mA,4-20mA,0-5V,0-10V and so on.

Overload

1.2 times rated (continuous); 2 times rated/1 second;

Power consumption

Voltage: ≤0.2VA, current ≤0.1VA

Accuracy class

Class 1

Function

Display

8-bit segment LCD screen (LCD)

Communication Interface

RS485, infrared

Communication protocol

Modbus-RTU,DL/T 645-2007

Switch

Switch output

2 Relay outputs, 2A/30VDC or 2A/250VA

Switch input

2 dry contact inputs

Pulse output

A second pulse output, a energy pulse output

See the SYS->PLUS display in the meter menu setting

For example: The meter displays 100, which is 100imp/kWH

Power Supply

Voltage range

AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)

Power consumption

≤ 3W

Power frequency withstand voltage

Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1minPower supply // Relay output // Voltage input // Current input 3kV/1minPulse output // Communication interface // Switch input 2kV/1min

Insulation resistance

≥ 40M Ω

Average barrier-free working hours

≥50000h

Environment

Temperature

Normal operating temperature: -25 °C ~ +65 °C;

Limit working temperature: -40 °C ~ +70 °C;

Storage temperature: -40ºC~+80ºC

Humidity

≤93%RH, no condensation, no corrosive gas

Altitude

≤2500m

 


Wiring
Wiring with Shunt
Wiring with Hall Sensor


Application
Solor PV Power Distribution Monitoring Solution
 
Practical Application in Solar PV with Energy Storage Inverter

Practical Application in Solar PV with on-grid Inverter

 
 

 
Product Tag:
Related categories:
Scroll to Top