Ephipot Electric Vlf Very Low Frequency Hipot Cable Test Instrument

Min.Order: 1
Product origin: Wuhan, Hubei, China
Infringement complaint: complaintComplaint
US$ 2200 ~ 5900

Description

 EPHipot Electric VLF Very Low Frequency Hipot cable test instrument


General Information:
VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear, and other electrical apparatus.


A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.


Feature:
  • Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
  • Touch screen, large LCD can display waveform clearly, and test report can be printed. Built-in printer
  • Multiple protections (overvoltage protection, overcurrent protection at HV/LV sides). When the output is beyond the limitation, the control unit will shut itself down within 10ms.
  • Easy operation: simple wiring and operation.
  • Safe and reliable: the controller and the high-voltage generator are connected at low voltage, photoelectrically controlled, safe and reliable to use.
  • Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
  • Large test range: 0.1Hz, 0.05Hz and 0.02Hz multi-frequency selection, large test range.
  • Portable design, small size and light weight: it is very convenient for outdoor operation.
 
Peak voltage:30kV
Output frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
Fuse: 10A
Maximum load capacity: 1.1μ[email protected], 2.2μ[email protected], 5.5μ[email protected]
Measurement accuracy:3%
Voltage positive and negative peak error:≤3%
Voltage waveform distortion:≤5%.
Working environment:Temperature: -10ºC-+40ºC, 85%RH.
Indoor or outdoor
Weight: 35kg
Power supply:220V 50/60Hz
The capacitance of the tested object shall not exceed the maximum rated capacitance of the instrument.
 
ModelRated voltage Load capacityFuseWeight
EPVLF-34/1.134kV
(peak 30kV)
0.1Hz ≤1.1µF10ACombined type 35kg
0.05Hz ≤2.2µF
0.02Hz ≤5.5µF
EPVLF-40/1.140kV
(peak)
0.1Hz ≤1.1µF10Acontroller:4kg
Booster:40kg
0.05Hz ≤2.2µF
0.02Hz ≤5.5µF
EPVLF-50/1.150kV
(peak)
0.1Hz ≤1.1µF20AController:4kg
Booster:45kg
0.05Hz ≤2.2µF
0.02Hz ≤5.5µF
EPVLF-60/1.160kV
(peak)
0.1Hz ≤1.1µF20AController: 4 kg
Booster:50 kg
0.05Hz ≤2.2µF
0.02Hz ≤5.5µF
EPVLF-80/1.180kV (Peak)0.1Hz ≤1.1µF20AController: 4 kg
Booster:50 kg
0.05Hz ≤2.2µF
0.02Hz ≤5.5µF