SR81/SR868 3000W Solar Controllers for Split Pressurized Solar Hot Water Heater

Min.Order: 1
Product origin: Changzhou, Jiangsu, China
Infringement complaint: complaintComplaint
US$ 58 ~ 64

Description

SR81/SR868 3000W Solar Controllers for Split Pressurized Solar Water Heater

1. Produuct Introduction

1.1 Overview

  • SR81 is an upgraded version of SR868C8.

  • SR81/SR868 is used in a split pressurized solar water heater system.

  • Intelligently controlled by the latest high-performance microcontroller from NXP.

  • All devices use industrial-grade standards to operate in cold, high-temperature, and humid environments, while using a clock chip for precise timing control.

  • The controller is LCD type, with beautiful appearance, stable and reliable performance, easy to install, as the most ideal accessory product for split pressure solar water heater.

1.2 Applications capacity

  • Max.number of collectors:1

  • Max.number of storage tanks:1

  • Max.number of relays:4

  • Max.number of sensors:5

  • Max.number of visualization application system: 1

1.3 Main functions

  • DATE---Date setting

  • Timed heat---backup heating

  • Circle---Hot water circulation

  • LOAD---Setup Loading tank1

  • COL---Collector1

  • PUMP---Pump control mode

  • COOL---Cooling function

  • AUX---Auxiliary function

  • MAN---Manual mode

  • BLPR---Blocking protection function

  • OTDI---Thermal disinfection function

  • FS---Flow meter type selection.

  • UNIT---C-F unit switch

  • RST---factory setting

  • PASS--- password set

  • Holiday function

  • Screen Protection

  • Trouble Protection

  • Trouble Checking

1.4 Delivery scope

ComponentsQuantitiesRemarks
Controller1pcSR81
Operation manual1pc 
PT1000 sensor1pc∅ 6*50mm,cable length 1.5mm
NTC10K2pcs∅ 6*50mm,cable length 3m
Accessory bag1pc 
Power cable1pc 
 

2. Technical Parameters

2.1 Technical parameters

ParameterValue
Size of Keypad120mm×120mm×18mm
Size of Controller1.5KW version:187mm×128mm×46mm  3KW/4KW version:218mm×165mm×55mm
Power supplyAC100~240V 50~60Hz
Power consumption< 2.5W
Measure accurate± 2ºC
Measure scope of collector sensor-10~220ºC
Measure scope of tank sensor0~110ºC
Available power of R1 electrical themal trace< 5000W
Available pump P2 can be controlledpump power <200W
Available electrical heater can be controlled H11pc(1.5KW version)<1.5KW                          1pc(3KW version)<3KW                                1pc(4KW version)<4KW
T1Collector:1*PT1000,≤ 500ºC(Sillicon cable ≤ 280ºC)
T2,T3NTC10K,B=3950,≤ 135ºC(PVC cabke ≤ 105ºC)
T4,T3Optional sensor:                            NTC10K,B=3950,≤ 135ºC(PVC cabke ≤ 105ºC)
Amblent temperature-10~50ºC
Water proof gradeIP41

2.2 Optional accessories

2.2.1 Electromagnetic relay : SR802,can control electric heating of ≤4000W.

Contactor unit of high power: SR802

 

When user selects electrical heater as back-up device, we recommend using SR802 unit connecting controller and electrical heater.

Technical data of SR802 Dimension: 100mmx100mmx65mm.

Power supply: 180V ~ 264V / AC 50 / 60Hz.

Suitable power: ≤ 4000W.

Available ambient temperature: -10 ~ 50oC Water proof grade: IP43.

 

3. Product Installation

3.1 SR208C Installation diagram