Vlf 80kv Very Low Frequency AC Hipot Test Equipment for Cable Withstand Voltage Testing

Min.Order: 1
Product origin: Chongqing, China
Infringement complaint: complaintComplaint
US$ 5000 ~ 10000

Description

I. Introduction:

This Ultra Very Low Frequency Test Equipment combines the advanced technology of modern digital conversion, fully computer control, automated boost, buck, measurement and protection.Human intervention can carried out during the automatic step-up process.
The VLF Test Equipment is suitable for testing cables, transformers, switchgear, Rotating machinery, and other electrical apparatus.

II.Advantages

★     Small sizes and light weight

★     large-screen LCD (clear and intuitive)

★     Test report can be printed out with inbuilt printer

★     Meet the power industry standards
★     Easy operation


III.Main Features

    ★   Data of current and voltage are obtained directly through the sampling of high-pressure side and it is true and accurate.

    ★   Over-voltage protection: the hipot test equipment will shut down to protection within 20 ms when the output voltage is exceeding limiting values of setting.

    ★   Over-current protection: design for dual protection of high and low voltage, downtime protection can be accurately set in high-pressure side.The VLF Hipot Test Equipment will be shut down for protection and the action time is less than 20 ms when the current of low-voltage sides exceeds reacted current.

    ★   High-voltage output protection resistor design in the body boost and additional outside resistor is not needed.

    ★   Closed-loop negative feedback control circuit of high and low voltage.
     

      III. Technical Specifications of VLF Test Equipment   :

      1, Output frequency: 0.1Hz,0.05Hz,0.02Hz.

      2, Accuracy: ± (3% of full scale +0.5 KV)

      3, Voltage waveform distortion: ≤5%

      4, Condition of use: indoor, outdoor, temperature:  -10ºC∽+40ºC, humidity :≤85%RH

      5, Power supply: AC50 Hz, 220V ±5%

               

      Model

      Rated Voltages

      Load Capacity

      Fuse

      Weight

      Application

      VLF-30KV

      30kV

      (peak )

      0.1Hz,≤1.1µF

      10A

      Control :6KG

      Booster :30KG

      10KV Cables,Generator

      0.05Hz,≤2.2µF

      0.02Hz,≤5.5µF

      VLF-40KV

      40kV

      (peak )

      0.1Hz,≤1.1µF

      20A

      Control :6KG

      Booster :50KG

      15.75KV Cables,Generator

      0.05Hz,≤2.2µF

      0.02Hz,≤5.5µF

      VLF-50KV

      50kV

      (peak )

      0.1Hz,≤1.1µF

      20A

      Control :6KG

      Booster :50KG

      15.75KV Cables,Generator

      0.05Hz,≤2.2µF

      0.02Hz,≤5.5µF

      VLF-60KV

      60kV

      (peak )

      0.1Hz,≤0.5µF

      25A

      Control :6KG

      Booster I:30KG

      Booster II:33KG

      18KV and below 
      Cables,Generator

      0.05Hz,≤1.0µF

      0.02Hz,≤2.5µF

      VLF-80KV

      80kV

      (peak )

      0.1Hz,≤0.5µF

      25A

      Control :6KG

      Booster I:30KG

      Booster II:50KG

      35KV and below 
      Cables,Generator

      0.05Hz,≤1.0µF

      0.02Hz,≤2.5µF

      Above model is the common requirement. It also can be customized for different voltage and load capacity.

       

      Factory overview


      Customer Feedback 

      Chile
      Germany


      USA

      Transporation

      FAQ

      1.What's the delivery time?
      About 10 working days.

      2.What's your payment terms?
      30% paid by T/T in advance,70% paid by by T/T before shipping.

      3.What's your guarantee terms?
      The warranty of all products is 1 year.During this period,we are responsible for all faults caused by us.And we can supply life-long technical support. 

      4.Can you supply training?
      We can supply training in our factory and online training for free.If onsite installation and training are required,please pay for tickets,accommodation and salary USD150/Day for every person.