Key Name | Function | Description |
MENU | Enter Main Menu / Exit. | |
LOCK* | Keep the key pressed for 2 seconds : Key-locking / Key-unlocking. | |
Cursor shifts right. Display the previous interface or option. | ||
Display the next interface or option. Digit input: +1 ( 0~9 loop). | ||
8 | ENT | Enter / Save / Clear Alarm. |
Pin | Description |
POWER | DC24V Power Input Port |
DC- | DC Input -. |
DC+ | DC Input +. |
RS485[COM1] | RS485 Digital Communication Port 1 |
B- | Data -. |
A+ | Data +. |
AO | Analog Output Port [Definable] |
mA+ | 4~20mA Current Signal Output +. |
mA- | AO Output -. |
CAN | CANBUS Digital Communication Port |
L | Data -. |
H | Data +. |
DO | Switch Output Port [Definable] |
DO+ | Relay Switch Signal Input +. |
DO- | Relay Switch Signal Input -. |
Contact Capacity of Relay Switch: AC250V/DC24V, 1A . |
Pin | Description |
LOADCELL | Loadcell Port |
S- | Weighing Signal Input +. |
S+ | Weighing Signal Input -. |
E- | Excitation Voltage -. |
E+ | Excitation Voltage + [DC10V]. |
SHD | Shield Ground. |
SPEED | Speed Sensor Port |
VS- | Voltage Output -. |
SIN | Pulse Signal Input. |
VS+ | Voltage Output + [DC12V]. |
Main Menu | Second Menu | Description |
F1 Setting | 1 Scale[Basic] | Basic scale parameters setting. |
1+Scale[Extra] | Extra scale parameters setting. | |
2 Control[Basic] | Basic feeding control parameters setting. | |
2+Control[Extra] | Extra feeding and batching control parameters setting. | |
3 Flow | Flow parameters setting. | |
4 Speed | Speed parameters setting. | |
5 Load | Load parameters setting. | |
6 Unused | Unused. | |
7 Comm. Port | Communication parameters setting. | |
8 I/O | Input/output parameters setting. | |
9 Display | User interface parameters setting. | |
10 Unused | Unused. | |
F2 Calibration | 1 Zero Cal. | Zero Calibration without loading for correcting Zero Value. |
2 Span Cal. Dyn. | Dynamic Span Calibration with loading measured materials or Poise Weights for correcting Span Coefficient. | |
3 Span Cal.Stat1 | Static Span Calibration with a measured chain weight as a continuous and steady load on the running belt weigher for correcting Span Coefficient. | |
4 Span Cal.Stat2 | Static Span Calibration with a measured Hanging Weight as a steady load on the running belt weigher for correcting Span Coefficient. | |
5 Span Cor. Seg. | Segmenting Span Correction. After doing Dynamic or Static Span Calibration, further corrections for 3 [AD Value: 0~60000] linear segments are optional for correcting Correction Coefficient 1~3. | |
6 Speed Cal. | Speed Coefficient Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Speed Coefficient. | |
7 Length Cal. | Belt Length Calibration. Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Belt Length. |
Main Menu | Second Menu | Description |
F3 Unused | Unused. | |
F4 Data Clearing | 1 Clear Screen | Clear Totalized Weight and Totalized Weight Pulse Count. But Totalized Weight of Current Shift will not be cleared, so this operation has no effect on recording of weight per shift. |
2 Unused | Unused. | |
3 Unused | Unused. | |
F5 Security | 1 Auto-locking | If there is not any keypad operation in one minute and it's not in the processes of 'F2 Calibration' & 'F6 Factory Adj.', the controller will lock the keypad and return to 'Main Display Interface' automatically. |
2 Key-locking | Locking keypad. | |
3 Key-unlocking | Unlocking keypad. | |
4 Password Set | Exfactory Password: 000001. | |
5 RAM Reset | Restore to factory defaults. | |
F6 Factory Adj. | Special for manufacturer. | |
F7 Product Info. | Only for query. | |
1 Version No. | Version No. | |
2 Serial No. | Serial No. | |
3 Exfactory Date | Exfactory Date. | |
4 Audit Counter | Audit Trail Counter [0~99999999] for Scale parameter's modification. | |
5 Unused | Unused. |
Changsha SUPMETER Technological Co., Ltd., as a council member of China Weighing Instrument Association (CWIA), is a high-tech enterprise which specializes in designing and manufacturing weighing/batching controller, force measuring controller, explosion-proof controller and related system software.
Since founded in 2004, SUPMETER is persisting in doing the same thing of 'customizing satisfied products for you and building win-win cooperation with you' and insisting on the core idea of 'Being Super in Meter and Being Perfect in Service'. On the quality basic of 'Accurate Weighing, Quick and Steady Control, Standard Communication Bus and Protocol, Suitable for Industrial Environment', SUPMETER is doing the best to meet your individual requirements and to reach the enterprise goal of 'Outstanding Quality, Continuous Improvement, Effective Service and Customer Satisfaction'.
The products of SUPMETER have been sold to over 1000 weighing equipment manufacturers from China, Germany, USA, Canada, Australia, Russia, Ukraine, Uzbekistan, Turkey, Pakistan, India, Thailand, Vietnam, Philippines, Malaysia, Indonesia, Singapore, Sri Lanka, South Africa, Nigeria, Zimbabwe, Iran, Saudi Arabia, Jordan, United Arab Emirates, Oman, Palestine, Mexico, Brazil, Argentina, Venezuela, Honduras, Bolivia, Chile, Peru and other countries and regions. And we have built long-time relationship of technical exchange and co-development with many famous enterprises. By tracking and applying international advanced technology and combining with all kinds of typical applications from the worldwide customers, SUPMETER has developed multiple high-quality products for customers and became a famous enterprise and brand in weighing, batching and force measuring field.
We will do our best to make our development more high-efficiency, quality more superior, service more enthusiastic and price more reasonable. SUPMETER, as your faithful team of product-development and technical service, is one of your best choices.
Our advantage is that we can customized the software to our customer's requirements.