Operation mode | Automatic transition of CV and CC |
Input voltage | AC380V±10%,50Hz±10% |
Output | Approximate 0 ~ rated voltage value continuously adjustable |
Approximate 0 ~ rated current value continuously adjustable | |
Voltage stabilization accuracy | Source effect: ≤ 0.2% of rated value (only due to input source voltage variation ±10%, output voltage change rate) |
Time drift: ≤ 0.2% of rated value (only the change rate of output voltage caused by continuous working time more than 8 hours) | |
Load effect: ≤ 0.2% rated value (only the change rate of output voltage caused by the change of output current from zero to rated value) | |
Steady current accuracy | Source effect: ≤ 0.1% of rated value (only due to input source voltage variation ±10%, output voltage Change rate) |
Time drift: ≤ 0.3% of rated value (only output voltage change rate caused by continuous working time more than 8 hours) | |
Load effect: ≤ 0.2% rated value (only the change rate of output voltage caused by the change of output current from zero to rated value) | |
Output ripple | Under voltage stabilization: ≤ 0.3% + 10mV (measured at 80% ~ 100% rated output) |
Efficiency | ≥95% |
Setting of output voltage and current | Ten turn potentiometer, external 0-10V or 4-20mA control signal |
Power factor | cosΦ= 0.95 |
Output stability | ≤0.3%(change rate of output voltage every 8 hours after starting up for half an hour) |
Output voltage regulation range | Approximately 0 ~ the rated voltage is continuously adjustable |
Output current regulation range | Approximately 0 ~ rated current value continuously adjustable |
Protection mode | Overvoltage, overcurrent, overheating and short circuit protection alarm function; The output can be turned off within 10us |
Display mode | LCD |
Display accuracy | 0.01KV; 0.01A(Note: the display accuracy of different specifications of power supply may be different) |
Error of voltage and ammeter of the whole machine | ≤±0.5%(measuring range 50% ~ 100% rated value) |
Intelligent computer control function | It is directly connected with PC through RS232 or 485 interface, and the output voltage and current value are controlled by special software. The working state of power supply can be monitored in real time on the computer to accurately grasp the load characteristics( (optional) |
Overload capacity | Less than 1.2 times of rated current, it still works normally |
Operation mode | Long term full load continuous operation |
Environment | Place of use: indoor use only temperature Temperature: - 20 ºC ~ 40 ºC Air humidity: ≤ 80% |