Industrial Standby Power Diesel Generator Set Soundproof 350 kVA Generator Diesel

Min.Order: 1
Product origin: Fuzhou, Fujian, China
Infringement complaint: complaintComplaint
US$ 25000 ~ 28000

Description
Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.












 






ShangHai Diesel Engine Generator Set  GF/GFS-SC Series
 
 
Generator with ShangHai Diesel Egnine 50Hz
 
Generator Set Performance Engine SpecificationOpen GensetSoundproof type
Genset Model50Hz OutputEngine ModelCylinderGovernorDisplacementDimensionWeightDimensionWeight
50HzPrime StandbyCons 100%(L/H)LL*W*H (mm)KGL*W*H(mm)KG
KVAKWKVAKW
GF/GFS-SC636350695515.1SC4H95D24LElec4.31980*880*153010062900*1080*20501800
GF/GFS-SC808064887019SC4H115D24LElec4.31980*880*153010662900*1080*20501800
GF/GFS-SC100100801108822.2SC4H160D24LElec4.32000*930*160011412900*1080*20501850
GF/GFS-SC113113901249925SC4H160D24LElec4.32000*930*160011412900*1080*20501850
GF/GFS-SC16016012817614035.7SC8D220D26LElec8.272440*1080*180015363500*1080*21502350
GF/GFS-SC17017013618715036.5SC7H230D26LElec6.52440*980*170015363500*1080*21502350
GF/GFS-SC18018014419815840.7SC8D250D26LElec8.272490*1080*180016043700*1100*21502400
GF/GFS-SC22522518024719849.6SC9D310D26LElec8.822490*1080*180017053700*1100*21502550
GF/GFS-SC25025020027522054.1SC9D340D26LElec8.822600*1080*180017763700*1100*21502550
GF/GFS-SC30030024033026467.5SC13G420D26LElec12.883030*1400*190028964350*1500*22203990
GF/GFS-SC31331325034427570.4SC13G420D26LElec12.883030*1400*190028964350*1500*22203990
GF/GFS-SC37537530041333081.2SC15G500D26LElec14.163030*1400*190030444350*1500*22204100
GF/GFS-SC450450360495396100.4SC25G610D212VElec25.83630*1720*225040784650*1800*25205300
GF/GFS-SC500500400550440113.1SC25G690D212VElec25.83630*1720*225040784650*1800*25205300
GF/GFS-SC625625500687550141SC27G830D212VElec26.63630*1720*225043284950*2000*25206000
GF/GFS-SC750750600825660174.9SC33W990D26LElec32.84360*1620*2160682020 container10000


 





 




























-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
IconIndicator LightReasonFault Analysis and Solve Method
High Water Temperature AlarmHigh Water Temperature AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure AlarmLow Oil Pressure AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level AlarmLow Fuel Level AlarmWhen Fuel level has been detected by sensor fitted to the daily tank,the light is off.Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault AlarmBattery Charger Fault AlarmThe Charing System has fault while engine still running,the light is off.Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure AlarmCrank Failure AlarmWhen Generator set fail three times(or six times) in arow starting,the light is onIt is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping AlarmOverload or Breaker Tripping AlarmWhen Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out.For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 Welcome your further contact and sending inquiry!


















 
 

 