Product Name | Parking Boom Barrier |
Voltage | 220 ~ 240V |
Power | 90W |
Arm length | 1 ~ 6 meters |
Arm Gate Material | Aluminum Alloy |
Size of Housing | 405 * 292 * 1019 mm |
Housing Material | Galvanized Plate |
Rail Lifting Time | 6 seconds |
Working Temperature | -25 °C ~ 80 °C |
Working Humidity | 5% ~ 95% |
Warranty | 1 Year |
Power supply: 220VAC 50HZ / 110VAC 60HZ
Motor's power: 90W 220VAC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20oC-50oC
Protection class: IP55
Power supply: 220VAC 50HZ / 110VAC 60HZ
Motor's power: 80W 24VDC
Max length of boom: 6m
Time for up/down: 3S( for 1~3m),6S( for 4~6m)
Environment temperature: -20oC-50oC
Protection class: IP55
Number | Trouble | Cause | Shooting |
1 | Motor of Barrier does not work | 1,No power supply | 1,Check power supply |
2,Break fuse | 2,Change fuse | ||
3,Motor is damaged | 3,Change the motor | ||
2 | Barrier can open but can not close | 1,Photocell is not connected properly | 1,Connect the photocell |
2,Photocell beam is block off | 2,Clear out obstacle | ||
3,Photocell is broken | 3,Change a new device | ||
3 | Barrier can open (close) but can not close (open) | 1,Position of limit switch is not correct | 1,Adjust position |
2,Limit switch is damaged | 2,Change limit switch | ||
4 | Barrier can not locate accurately | 1,Distance of limit switch is too large | 1,Adjust position of limit switch |
2,Limit switch is wrong | 2,Change limit switch | ||
3,Magnetic-stell's position is wrong | 3,Re-adjust the position | ||
5 | Release device of Barrier is doesn't work | 1,Operating handle is broken | 1,Change the handle |
2,Worm gears are jammed | 2,Rotate the pinion | ||
6 | Push the "OPEN" button but the Barrier gate close | Whether "+MOTOR-" wires are connected wrong | Connect correctly according to wiring diagram |
7 | Motor of Barrier can work but boom can not work | Compression spring of clutch is dead | Change the spring |